background image

 

5. Adjust the suction and the pace 

  Press the +/- to adjust the level. 

 

We recommend you to start pumping the milk with level 1 of suction and 
pace for your first use. 

  After you are familiar with the operation, you can adjust the level depending on 

your situation and needs. 

  When you need to release from milk engorgement, you can try a higher level of 

suction. 

  You can press the “M” button for longer than 2 seconds to switch between 

“massage mode” and “pump mode”. 

  You can change to “massage mode” after pumping to release your breast or 

stimulate lactation. 

 
7. Switching off 

  When finish pumping, press the POWER button and unplug the adapter.   

 
8. Cleaning 

  Please clean the pump body, massage cushion, valve, bottle, teat, screw ring, 

sealing disc immediately after every use. 

  Cover, sealing ring, pedestal, and connection need cleaning every week.   

 

Attention: Clean the valve carefully not to break the tip. 
                  Never use a brush or detergent to clean. 

 
9. Sterilizing               

  Please clean and sterilize all PP and silicone accessories. TIPS BELOW: 

a. Scalding                                                                                           

  Put the accessories in the boiling water for 5 mins 

  Never let the accessories touch the side of the pots to prevent from distortion 

b. Steam sterilization by the microwave 

  Please use sterilization containers for microwave sterilization   

  Please sterilize in the microwave according to the information.   

c. Steam sterilization 

  All the accessories can be sterilized by a steam sterilizer. 

D. Other methods 

  Never use dry heat, UV or

 

dish-washing machine to sterilize. 

Attention: Please keep all parts dry after sterilizing 
                  Please follow sterilzer instructions.

 

 
10. Storing milk 

  Store the milk in either the fridge or freezer after collecting. 

 

Summary of Contents for 2 in 1 Electric Breast Pump

Page 1: ...l suction cycle ü Automatic massage function ü Mains power or battery operated ü 9 levels of suction pressure and pace ü Compatible with most major brand bottles ü Hospital strength ultra quiet motor Please read the information on this document carefully and retain for future reference ...

Page 2: ...ex 1 Features 2 Technical parameters 3 Accessories 4 Assembly method 5 Usage Ready to use Automatic pumping Feeding Storing Cleaning Sterilizing 6 Troubleshooting 7 Attention 8 Packing list 9 Warranty card ...

Page 3: ...mport 100 240 VAC 50 60HZ Export 5V DC 400mA wattage 3W Battery AA battery 1 5V 4 Pumping intensity max 50 Kpa Suggested using time 20 30 mins every time Using condition 5 40 C RH 80 3 Accessories Pump body PP 120 Main device Connection PP 120 Adapter Cover PP 120 Massage cushion Silicon rubber 120 Silicone diaphragm Silicon rubber 120 Pedestal PP 120 Screw ring PP 120 Screw ring PP 120 Bottle cap...

Page 4: ...ectric breast pump as below a Install valve onto lower pump b Screw bottle onto lower pump body body firmly without any leaks c Push silicone diaphragm onto the lower d Connect air tube onto upper pump body firmly without any leaks pump body and the air tube socket of the main device e Make sure the massage cushion is firmly attached without any leaks Use your thumb to press the massage cushion th...

Page 5: ...n and make you comfortable 2 Start to use Adjust your position and make sure that your are comfortable Grip the pump body and aim the massage cushion to the breast Turn on the Power button to start function 3 Massage mode After switching on the device it will automatically starts with 15 seconds of massage mode and then pump mode When you press the or breast pump will change massage mode to pump m...

Page 6: ...c immediately after every use Cover sealing ring pedestal and connection need cleaning every week Attention Clean the valve carefully not to break the tip Never use a brush or detergent to clean 9 Sterilizing Please clean and sterilize all PP and silicone accessories TIPS BELOW a Scalding Put the accessories in the boiling water for 5 mins Never let the accessories touch the side of the pots to pr...

Page 7: ... after defrosted Never defrost or warm the milk by microwave Please do not store the milk at room temperature 11 Feeding baby Please check the temperature before feeding Take out the bottle from the pump body and fit on the teat Feed baby when the milk is in suitable temperature Frozen milk needs to defrost and warm up to 38 42 before feeding the baby ...

Page 8: ...flow 1 Using a stronger suction level than necessary 2 There is water in the tubes 3 Bottle is too small Choose the a lower level Dry or change the tubes Change the bottle to another brand 7 Attention The product is individual do not share with other people Always unplug when it is not use Never use the breast pump in a damp place or in water If the main device drops into the water do not touch it...

Page 9: ... Teat Silicon rubber 1PCS 3 Pump body PP 1PCS 12 Silicone diaphragm Silicon rubber 1PCS 4 Screw ring Silicon rubber 1PCS 13 Bottle cap PP 1PCS 5 Windpipe cover PP 1PCS 14 Sealing disc Silicon rubber 1PCS 6 Windpipe Silicon rubber 1PCS 15 Valve PP 1PCS 7 Connection PP 1PCS 16 Main device 1PCS 8 Bottle PPSU 1PCS 17 Adapter 1PCS 9 Pedestal PP 1PCS 18 ...

Page 10: ...y below or your receipt If have any question please consult us at www aprebaby com au Name Tel Product name Mode Purchase shop Purchase date Address Service Attention Apre provides one year warranty service for main device and are not responsible for improper use ...