5–14
PacketMax 5000 Installation and Operation Manual, 10007678 Rev J
Chapter 5. Commissioning the Base Station
5.
Go to the “wsc” folder and copy “wsc1_0_0.D” file to the “/tffs0” of the MSC
Card.
shows the ftp screen, once the transfer is done.
6.
Click on the
Close
button and then click on the
Exit
button on the WS_FTP
client.
Figure 5-15
Ftp page - MSC upgrade
7.
Open the telnet session, by going on command prompt, to the PM 5000 MSC
card. Type “telnet Host Address”. For example, “telnet 10.226.0.5 5000” at the
C:/prompt.
8.
Click the
Enter
key. The vxWorks will prompt to enter the WSC card number
and the Login prompt will appear. The Login is “isp” and password is “isp”. The
PM 5000>
command prompt will show up when login is successful.
9.
Program the MSC bootrom by typing “sysBootImangePut “tffso/
bootrom_wsc.bin” at the command prompt. The password prompted for is “otre-
paotrepa”.
displays the telnet session. A message shows “
Are you
sure you want to continue (Y/N)
”. Type
Y
. It may take a few minutes before
the process begins. Once its done, the command prompt PM5000> returns.
Verify that the MSC and WSC cards bootup using the appropriate software
images that were FTPed to the “/tffs0” directory of the MSC card.
10.
Type the command “nvramConfigChange”. Confirm that the “MSC Main” and
“WSC Main” image file names match those that were FTPed using the above
steps.
Summary of Contents for PacketMAX 5000
Page 10: ...Preface Preface vi PacketMax 5000 Installation and Operation Manual 10007678 Rev J ...
Page 14: ...Table Of Content TOC 4 PacketMax 5000 Installation and Operation Manual 10007678 Rev J ...
Page 146: ...E 4 PacketMax 5000 Installation and Operation Manual 10007678 Rev J Chapter E Certifications ...
Page 150: ...F 4 PacketMax 5000 Installation and Operation Manual 10007678 Rev J Chapter F Troubleshooting ...