D–5
PacketMax 5000 Installation and Operation Manual, 10007678 Rev J
Chapter D. System Specifications
D.2 Physical interfaces of PM 5000 - 4 sector
Table D-2
Specifications for Interfaces of 4 Sector BS
Device
Interface
Type
Interface Spec / Standard
Connector Type
and Spec
PM 5000
Chassis
DC Power
Input
DC Power Input
Recommended Operating Range(1): -43 to -58 Volts
Absolute Maximum Range(2): -36 to -72 Volts
Qty=2, 3-Pin Terminal
Block
AC Power
Input
AC Power Input, 100 to 240V VAC Volts, 50 to 60 Hz
IED 320 CONNEC-
TOR
PM 5000
MSC Card
Backhaul -
Data “1000
Base-T”
1000 Base-T, Ethernet, IEEE 802.3, Auto Sense, MDI/MDI-
X
Maximum IP Packet Size:
1,600 bytes (including the
Ethernet Header and excluding the FCS)
RJ45 (Shielded)
Backhaul -
Data “100
Base-T””
100 Base-T, Ethernet, IEEE 802.3
Maximum IP Packet Size:
1,600 bytes (including the
Ethernet Header and excluding the FCS)
RJ45 (Shielded)
Main Man-
agement
“10/100
Base-T”
100/10 Base-T, Ethernet
Maximum IP Packet Size:
1,548 bytes (including the
Ethernet Header and excluding the FCS)
RJ45 (Shielded)
Main Man-
agement “RS
232”
Serial RS232
RJ11
SYNC
"Main"
Main Sync Input, Pulse-Per-Second (PPS), 1 Hertz, TTL
Voltage Levels
BNC, Input, Male, 50
Ohm
SYNC
"PW1000
Out"
Main Sync Output, Pulse-Per-Second (PPS), 1 Hertz, TTL
Voltage Levels
Use this port to Daisy Chain to Another PM5000 Unit or
Future PM3000 device.
Note: This port is also reserved for synchronization with
PacketWave 1000/760 (future possible feature), Pulse Per
Frame (PPF) format.
BNC, Output, Male,
50 Ohm
EXT. CLK “IN”
10 MHz Clock Input, TTL Voltage Levels
BNC, Input, Male, 50
Ohm
EXT. CLK
“OUT”
10 MHz Clock Output, TTL Voltage Levels
BNC, Output Male,
50 Ohm
SHELF MAN-
AGER
“TELCO”
Dry Relay Alarm Ports
Mini Sub-D, 15 Pin,
Female
SHELF MAN-
AGER “10-
Base T”
10 Base-T, Ethernet
Not Supported, For Internal Use Only
RJ45 (Shielded)
SHELF MAN-
AGER “RS
232”
Serial RS232 Port
Not Supported, For Internal Use Only
Audi Jack, Female,
3.5mm
WSC Card
IF
IF Port, 70 MHz
24 V Output Voltage
Type-F, Male, 75
Ohm
Summary of Contents for PacketMAX 5000
Page 10: ...Preface Preface vi PacketMax 5000 Installation and Operation Manual 10007678 Rev J ...
Page 14: ...Table Of Content TOC 4 PacketMax 5000 Installation and Operation Manual 10007678 Rev J ...
Page 146: ...E 4 PacketMax 5000 Installation and Operation Manual 10007678 Rev J Chapter E Certifications ...
Page 150: ...F 4 PacketMax 5000 Installation and Operation Manual 10007678 Rev J Chapter F Troubleshooting ...