Step 3. Connect the output connectors of the RSD-S-PLC in series to the string, the string 
open-air DC voltage is within the range of (0.6 ~ 1v) X #RSD-S-PLCs. (This range may vary 
due to different on-site environment.)

  NOTE: Do not connect homerun to inverter before finishing all strings connections and tests.

×

×

2022/05/27   Rev2.8 | Quick Installation Guide

2

Product information is subject to change without notice. (Please download manuals at www.APsmartglobal.com).

Bending Radius of the cable >50mm

   NOTE: When installing RSD-D cable, the bending radius of the cable near the casing must be greater than 50 mm.

NOTE:  Please use the same type of DC connector as the RSD in the system. The RSD damage caused by using 

different type of DC connector will not be covered by the warranty.