19
MEASUREMENT
AC Cont.
310XAC
320XAC
340XAC
360XAC
Current (rms)
Range
L
0.005 A - 1.200 A
0.005A - 2.400
A
x
x
H
1.00 A 13.00A
2.00 A - 26.00 A
0.05 A - 52.00 A
0.05 A - 78.00 A
Resolution
L
0.001 A
x
H
0.01 A
0.01 A
Accuracy
L
± (1% of r 5 counts)
± (1% of r 5 counts) @ 40 - 100 Hz,
± (1% of r 5 counts) @ 101 - 500
Hz > 0.1A, ± (1% of r 5 counts) @
501 - 1000 Hz > 0.2A
H
± (1% of r 5 counts)
Current (peak)
Range
0.0 A- 38.0 A
0.0 A - 76.0 A
0.0 A - 152.0 A
0.0A - 228 A
Resolution
0.1 A
Accuracy
± (1% of r 5 counts)
Power (W)
Range
L
0.0 W - 120.0 W
0.0 W - 240.0 W
x
x
H
100 W - 1300 W
200 W - 2600 W
0 W - 5200 W
0 W - 7800 W
Resolution
L
0.1 W
x
x
H
1 W
Accuracy
L
± (2% of r 15 counts) at PF ≥
0.2
x
x
H
± (2% of r
5 counts) at PF ≥
0.2
± (2% of r 5
counts) at PF ≥ 0.2
Power Apparent
(VA)
Range
L
0.0 VA - 120.0 VA
0.0 VA - 240.0
VA
x
x
H
100 VA - 1300 VA
200 VA - 2600
VA
0 VA - 5200 VA
0 VA - 7800 VA
Resolution
L
0.1 VA
x
x
H
1 VA
Accuracy
V x A, Calculated Value
Power Reactive (Q)
Range
L
0.00 VAR - 120.0
VAR
0.0 VAR - 240.0
VAR
x
x
H
0 VAR - 1300 VAR
0 VAR - 2600
VAR
0 VAR - 5200
VAR
0 VAR - 7800 VAR
Resolution
L
0.1 VAR
x
x
H
1 VAR
Accuracy
√(va)² - (w)², calculated value
Power Factor
Range
0 - 1.000
Resolution
0.001
Accuracy
W/VA, Calculated value and displayed to 3 significant digits
Crest Factor
Range
0 - 10.00
Resolution
0.01
Accuracy
Ap/A, Calculated value and displayed to 2 significant digits
MEASUREMENT
DC
310XAC
320XAC
340XAC
360XAC
Voltage
Range
0.0 - 420.0 V
0.0 - 420.0 V
Resolution
0.1 V
Accuracy
± (1% of r 2 counts)
± (1% of r 5 counts)
Current
Range
L
0.010 A - 1.200A
0.010 A - 2.400
x
x
Summary of Contents for 00310XAC
Page 16: ...10 310XAC 320XAC...
Page 24: ...18 Accuracy L 0 1 Hz 0 0 500 Hz H 0 2 Hz 501 1000 Hz...
Page 26: ...20 A...
Page 36: ...30...
Page 101: ...95 move back to the test screen...
Page 108: ...102...
Page 127: ...121 CONNECT CONNECT 0 1 0 1...
Page 130: ...124 Register...
Page 138: ...132...