7. Displayed Messages
During any abnormal conditions, there are several error messages that could be
indicated in the display. When an abnormal condition occurs the output will
disable and the alarm will sound. The Test/Reset LED indicator will also begin
flashing. Pressing the Test/Reset key will reset the audible alarm and the
abnormal condition will be displayed.
All error messages occur in abnormal conditions and
therefore must be recorded. Check the cause of the error to ensure the problem
is eliminated before restarting the operation, or contact Associated Power
Technologies, Inc., or our official distributors for further assistance.
Display
Message Definition
OTP
Over Temperature Protection
OCP
Over Current Protection
OPP
Over Power Protection
OVP
Output Voltage Protection
A-SH
Amplifier Shutdown Protection
7.1
OTP – Over Temperature Protection
Displayed if the heat sink of the instrument has exceeded 130º C. The voltage
and current displays will show the overloaded voltage or current respectively.
The LED indicator for the Test/Reset key will be blinking.
7.2
OCP – Over Current Protection
Displayed if the output current has exceeded 110% of maximum current rating for
1 second or there is a short circuit for 6 seconds. The LED indicator for the
Test/Reset key will be blinking.
7.3
OPP – Over Power Protection
Displayed if the output power has exceeded 110% of maximum power rating for 1
second. The LED indicator for the Test/Reset key will be blinking.
7.4
OUP – Output Voltage Protection
Displayed if the output voltage has exceeded 5 V of the setting voltage in the
0-150V range, or has exceeded 10 V of the setting voltage in the 0-300V range.
The LED indicator for the Test/Reset key will be blinking.