Operation 

 

Open the door, and put the Knives in the basket (Knifes should be washed and dried before placing 
inside the sterliser).    Ensure that the knives are held in the rack with the blade facing upwards and 
angled towards the back of the unit. The handle of the knife should be resting on the floor of the unit 
behind the front lip. Please see image below –   
 

   

 

Close the door. 

 

Connect the appliance to a suitable mains socket and turn on the power supply. 

 

There are 2 methods of operating the Knife Sterilser 

o

 

Turn the timer dial to the ‘On’ position - the lamp will continue to operate until the door is 
opened or the timer is returned to the      position (note – 120 minutes is the time required to 
ensure sterilisation) 

o

 

To use the timer function rotate the dial to the 120 minute position. The unit will then operate 
for 120 minutes (note – 120 minutes is the time required to ensure sterilisation)   

 

A safety switch turns off the lamp when the door is opened   

 

DO NOT look directly at the lamp 

 
 
Cleaning & maintenance 

 

Always turn off the appliance and disconnect from power supply before cleaning. 

 

Warm soapy water is recommended for cleaning. Cleaning agents may cause damage or leave 
harmful residues when used for a prolonged period on stainless steel.   

 

A APURO dealer or qualified technician should carry out repairs if required. 

 

 

Summary of Contents for DM079

Page 1: ...KNIFE STERILISER INSTRUCTION MANUAL MODEL DM079 A ...

Page 2: ...ispose of the packaging in accordance with the regulations of local authorities If the power cord is damaged it must be replaced by a APURO agent or a recommended qualified technician in order to avoid a hazard This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience or knowledge unless they have been given supe...

Page 3: ...ixing screws Once the screws are installed locate the appliance on the wall by aligning the locating holes on the back plate with the screws WARNING Ensure the substrate and fixings used to mount the Knife Steriliser are suitable to support the weight of the loaded unit If necessary seek professional help to ensure the shelf is safely mounted ...

Page 4: ...will continue to operate until the door is opened or the timer is returned to the position note 120 minutes is the time required to ensure sterilisation o To use the timer function rotate the dial to the 120 minute position The unit will then operate for 120 minutes note 120 minutes is the time required to ensure sterilisation A safety switch turns off the lamp when the door is opened DO NOT look ...

Page 5: ...ut correctly Shut the door Technical Specification Model Voltage Power Dimensions h x w x d mm Weight kg DM079 230v 50Hz 20w 600mm x 510mm x 150 mm 7 Electrical Wiring This appliance is supplied with plug and lead The plug is to be connected to a suitable mains socket This appliance is wired as follows Live wire coloured brown to terminal marked L Neutral wire coloured blue to terminal marked N Ea...

Page 6: ...aste disposal in your area APURO parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international independent and federal authorities APURO products have been approved to carry the following symbol All rights reserved No part of these instructions may be produced or transmitted in any form or by any means electronic mechanical photoco...

Page 7: ... 2009 A2 2011 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 EN 55014 2 1997 A1 2001 A2 2008 IEC 60335 1 2012 EN62233 2008 Producer Name Apuro Producer Address 15 Badgally Road Campbelltown NSW 2560 I the undersigned hereby declare that the equipment specified above conforms to the above Legislation and Standard s Date 03 09 14 Signature Full Name Richard Cromwell Position Commercial Director...

Page 8: ...7 DM079 A_V3 ...

Reviews:

Related manuals for DM079