!
!
NOTICE:
Local codes regarding installation vary greatly from one area to another. The
National Fire Protection Association, Inc., states in its NFPA96 latest edition that local
codes are “Authority Having Jurisdiction” when it comes to requirement for installation of
equipment. Therefore, installation should comply with all local codes.
4
!
!
WARNING:
Keep the appliance free & clear of all combustible substances.
If gas odor is
detected at any time, immediately shut unit down at the main shutoff valve. Do not permit
any open flames in the area of the appliance. Immediately contact an authorized Service
Agency or your local Gas Supplier for service.
SPECIFICATIONS AND DIMENSIONS
GGT-18
18 (457)
26 (661) 17-3/4(451)
1
37,500/11
37,500/11
6/10(15/25)
GGT-24
24 (610)
26 (661) 17-3/4(451)
2
25,000/7.3
50,000/14.6
6/10(15/25)
GGT-36
36 (915)
26 (661) 17-3/4(451)
3
25,000/7.3
75,000/22
6/10(15/25)
GGT-48
48 (1220) 26 (661) 17-3/4(451)
4
25,000/7.3
100,000/29.3
6/10(15/25)
GGM-18
18 (457)
26 (661) 17-3/4(451)
1
37,500/11
37,500/11
6/10(15/25)
GGM-24
24 (610)
26 (661) 16-3/4(426)
2
25,000/7.3
50,000/14.6
6/10(15/25)
GGM-36
36 (915)
26 (661) 16-3/4(426)
3
25,000/7.3
75,000/22
6/10(15/25)
GGM-48
48 (1220) 26 (661) 16-3/4(426)
4
25,000/7.3
100,000/29.3
6/10(15/25)
MODEL
WIDTH
IN. (MM)
DEPTH
IN. (MM)
HEIGHT
IN. (MM)
# OF
BURNERS
BTU/kW PER
BURNER
TOTAL
BTU/kW HOUR
W.C.
IN. (’Mbar’)
Griddle Surface Dimensions
MODEL
WIDTH
IN. (MM)
DEPTH
IN. (MM)
GGT-18 and GGM-18
17 13/16” / (452)
19 ½” / (496)
GGT-24 and GGM-24
23 13/16” / (605)
19 ½” / (496)
GGT-36 and GGM-36
35 13/16” / (910)
19 ½” / (496)
GGT-48 and GGM-48
47 13/16” / (1215)
19 ½” / (496)
GENERAL INSTALLATION INSTRUCTIONS
Ensure gas supply and gas type, as shown on unit nameplate agree.
Unit installation must conform with the National Fuel Gas Code, ANSI Z223.1-1996, the National Gas
Installation Code, CAN/CGA-B149.1, or the Propane Installation Code, CAN/CGA-B149.2 as applicable
and in accordance with local codes.
Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand. Level the
unit by turning the adjustment screw at the bottom of each leg. Do not slide unit with legs mounted, lift if
necessary to move unit.
Pipe threading compound must be resistant to the action of liquefied petroleum gases.
WARNING:
Do not obstruct either the air inlet (underneath unit) or the ventilation air (back
of unit). Provisions must be provided to provide an adequate air supply to the griddle.
!
!