480V Only
5
5
5
5
5
5
5
5
17
18
18
18
18
16
15
14
4
9
3
2
6
1
10
17
16
15
14
DS1
DS2
DS3
13
1
2
12
3
7
4
8
11
10
11
6
9
8
7
13
12
Incoming Supply
See Notes 1 & 5
Make equipment
ground
connection here
Ground Lug
Griddle
(Bottom View)
TB2 L1 L2 L3 E1
Thermostat
Bulb
Trough
Side
Indicator
Lights
HS1
Sleeve
(208 & 240V Only)
HS2
HS3
HS4
DS4
Single wrap
tape around
all pilot light
leads
Wire Nut
5
5
5
5
5
5
5
5
14
14
16
16
17
17
15
6
7
7
8
8
9
10
11
12
12
13
13
4
4
9
3
3
6
2
2
11
1
1
10
18
18
18
18
15
DS1
DS2
DS3
EGD48GB WIRING DIAGRAM
6”
12”
12”
12”
6”
Sensing Locations
SENSING LOCATIONS
11
Note:
1. Wiring shown 3
phase only.
5. Servicing Only -
Power source must
be disconnected
before servicing
griddle.