background image

APW WYOTT Foodservice Equipment Company

P.O. Box 1829

Cheyenne, WY 82003

+1 (307) 634-5801 Phone

+1 (800) 752-0863 Toll Free

+1 (307) 637-8071 Fax

www.apwwyott.com

INSTALLATION AND OPERATING INSTRUCTIONS

FRY28, FRY30, & YDS5

P/N 8806302 9/05

R

WARNING:

Improper installation, operation, service or maintenance can cause

property damage, injury or death. Utility location is CRITICAL. Read and understand

these instructions thoroughly before positioning, installing, maintaining or servicing

this equipment.

!

!

1

IMPORTANT FOR FUTURE REFERENCE

Please complete this information and retain this manual for the life of the equipment. For

Warranty Service and/or Parts, this information is required.

Model Number

Serial Number

Date Purchased

DISHING STATIONS

Summary of Contents for FRY28

Page 1: ...eration service or maintenance can cause property damage injury or death Utility location is CRITICAL Read and understand these instructions thoroughly before positioning installing maintaining or servicing this equipment 1 IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment For Warranty Service and or Parts this information is requi...

Page 2: ...allation and from there to an independent earth connection WARNING A factory authorized agent should handle all maintenance and repair Before doing any maintenance or repair contactAPW Wyott 2 Congratulations on your purchase of APW Wyott Modular Assembly Pack Station APW Wyott takes pride in the design and quality of our products When used as intended and with proper care and maintenance you will...

Page 3: ... Number 0 M1982 General Requirements Canadian Electrical Code Part II 109 M1981 Commercial CookingAppliances NOTICE Local codes regarding installation vary greatly from one area to another The National Fire Protection Association Inc states in its NFPA96 latest edition that local codes are Authority Having Jurisdiction when it comes to requirement for installation of equipment Therefore installati...

Page 4: ...til after the equipment is uncrated a request for inspection must be made to the carrier within 15 days The carrier should arrange an inspection NOTICE If you have questions concerning the installation operation maintenance or service of this product write Technical Service Department APW WYOTT Foodservice Equipment Company P O Box 1829 Cheyenne WY82003 NOTICE Installation and start up should be p...

Page 5: ... the data plate Connect only to 1 or 3 phase as listed on the data plate WARNING Electrical and grounding connections must comply with the applicable portions of the national electrical code and or other local electrical codes 5 STEP1 POSITION TABLE REVIEW STORE LAYOUT FOR EXACT LOCATION OF TABLE Place the table in the designated area Level table by using a level and turning the footpad on the adj...

Page 6: ...TCH OVERHEAD HEATER 760 W 208 V BOTTOM HEATER 400 W OVERHEAD HEATER 760 W 208 V L1 LIGHT PILOT LIGHT PILOT L2 L1 H1 H2 L1 L1 POWER SOURCE BROWN POWER SOURCE BROWN 12 10 GROUND L1 L2 NEUTRAL 21 NEUTRAL BLUE GROUND GREEN YELLOW ROPE HEATER L2 H2 H1 PIL L1 ON OFF PILOT INFINITE SWITCH TL ON OFF 13 PILOT ON OFF PILOT L2 H2 H1 PIL L1 INFINITE SWITCH TR L2 H2 H1 PIL L1 INFINITE SWITCH B OVERHEAD HEATER ...

Page 7: ...E CIRCUIT BREAKER HAS BEEN SIZED CORRECTLY FORTHISAPPLICATION FRY28 Remove cover for access to wires Remove plug as needed for wire routing Install wires and grommet Field to determine proper wire routing Blue 18 Neutral Brown 12 Power Source L1 Brown 10 Power Source L2 Green w Yellow 21 Ground End covers can be removed to run wires from one table to another FRY30 Remove plug as needed for wire ro...

Page 8: ...LOW L2 H2 H1 PIL L1 PILOT INFINITE SWITCH TL PILOT L2 H2 H1 PIL L1 INFINITE SWITCH TR L2 H2 H1 PIL L1 INFINITE SWITCH B OVERHEAD HEATER OVERHEAD LIGHTS OVERHEAD HEATER PILOT OVERHEAD HEATER OVERHEAD LIGHTS OVERHEAD HEATER OVERHEAD LIGHTS OVERHEAD HEATER ON OFF ON OFF ON OFF ON OFF POWER SOURCE BROWN L2 PILOT 1 1 1 7 2 7 2 7 2 3 3 5 4 5 4 4 5 8 6 8 6 6 8 9 10 9 10 10 9 11 11 12 13 13 12 12 13 14 15...

Page 9: ...ANGER ELECTRICAL SHOCK CAN KILL MAKE SURE POWER HAS BEEN DISCONNECTEDATTHE SOURCE BEFORE MAKINGTHESE CONNECTIONS WARNING MAKE SURE THE CIRCUIT BREAKER HAS BEEN SIZED CORRECTLY FORTHISAPPLICATION 9 GND L2 NEUTRAL LIGHT PILOT PWR SWITCH INCANDESCENT LIGHTS INIFINITE SWITCH OVERHEAD HEATER 760 W 208 V OVERHEAD HEATER 760 W 208 V L3 LIGHT PILOT LIGHT PILOT L2 L1 H1 H2 L1 LIGHT PILOT INIFINITE SWITCH L...

Page 10: ...op and frame in the same fashion since this might damage the cabinet finish If stainless steel surfaces become discolored scrub by rubbing only in the direction of the finish grain steel wool may leave particles that can rust and cause pitting 1 Always turn off and allow units to cool completely before cleaning Clean thoroughly before the first use 2 Daily remove any pans or food containers and wa...

Page 11: ...ower to the unit Turn on the red power switch to turn on the bottom heat The switch will illuminate indicating there is power to the unit Turn on the black power switch to turn on the overhead heaters and the lights The light will illuminate indicating there is power to the unit The unit has been calibrated at the factory to hold product 160 F to 180 F Wait about 30 to 45 minutes for the unit to h...

Page 12: ...h knobs are located behind the removable panel Remove single screw on the removable panel to access the adjustment knobs The factory set point for the overhead heaters is setting 5 Turn knob to a higher number for a warmer product and to a lower number for a cooler product Replace the removable panel so the setting is not accidentally moved from it s setting Wait 30 to 45 minutes to determine of t...

Page 13: ...lectrical shock Replace power switch Refer to the Operations section for the adjustment procedure for this particular unit Place the power switch in the OFF position and disconnect power from unit Warning Failure to do so may result in electrical shock Replace heater Place the power switch in the OFF position and disconnect power from unit Warning Failure to do so may result in electrical shock Ch...

Page 14: ...vice Hot line at 1 800 733 2203 This will give access to the nearestAuthorizedAPW Wyott Parts Service Distributor 1 Service work is performed by other than anAPW WyottAuthorized ServiceAgency 2 Other than GenuineAPW Wyott replacement parts are installed NOTICE WARRANTYWILLBE VOIDAND THE MANUFACTURER IS RELIEVED OFALLLIABILITYIF 14 5 SPECIFICATIONS DIMENSIONS MODEL WEIGHT CUBE F O B W D H FRY28 28 ...

Page 15: ...bs 81 Cheyenne WY ELECTRICAL V W A FRY30 15 13 654 28 972 13 562 35 998 27 216 TYP 56 000 WIRING CHANNEL DATA PLATE LOCATION 30 656 56 188 60 122 30 656 30 375 27 375 30 656 56 188 WIRING CHANNEL DATA PLATE LOCATION 30 656 60 122 27 375 30 375 13 654 28 972 13 562 35 998 27 216 TYP 56 000 ...

Page 16: ...LECTRICAL V W A YDS5 16 60 000 11 688 29 125 11 688 60 000 12 978 875 56 772 59 844 56 844 11 688 29 125 11 688 52 500 35 998 55 304 11 500 60 000 11 688 29 125 11 688 ELECTRICAL CONDUIT WIRING CHANNEL DATA PLATE LOCATION 52 500 29 125 11 688 55 304 35 998 11 500 11 688 60 000 56 844 59 844 12 978 56 772 875 ...

Page 17: ...ESCRIPTION QTY 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 15155 00 13062 00 13282 00 88690 00 88685 00 11010 00 48711 43 10004 00 48712 54 31007 54 87307 10 2807 12 81320 00 48711 51 48250 53 14311 17 15057 00 15058 00 48484 00 48484 02 3 2 3 1 2 2 1 2 2 1 3 1 1 1 2 1 2 4 2 4 Light Indicator 250V Switch Rocker 250VAC 10A Switch Infinite Label Bottom Switch Label Top Switch Connect...

Page 18: ...Bed Plate Distribution Roller 065w X 3 8 O D Plate Hold Down Snap Washer Panel Bottom Cover 4 24 30 1 1 1 4 4 4 1 1 13 1 13 2 16 17 18 19 20 21 22 23 24 25 26 27 28 48731 23 89784 00 14319 10 82055 00 14311 17 48731 19 16183 00 48711 51 48250 53 15057 00 15058 00 48484 00 48484 02 Panel Lower Enclosure Bushing 7 8 Snap Hyco Element 208V 760W Screw 1 4 20 X 1 2 Tr Hd Heat Cable 108 Panel OVS Right ...

Page 19: ...07 10 13282 00 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 ITEM P N DESCRIPTION QTY ITEM P N DESCRIPTION QTY Weldment Frame Top Dishing Station Pan Potato Bed Angle Wire Channel Channel Wire Cap Electrical Channel Pan Insert Divider Insert Panel L H End Panel R H End Weldment Shelf Top Shelf Mount Heater K L Dishing Station Mount Heater L H Cover Insulation Heater N D Assembly Ligh...

Page 20: ...nd 2 toasters or rollergrills which have in store service The following conditions are not covered by warranty Equipment failure relating to improper installation improper utility connection or supply and problems due to ventilation Equipment that has not been properly maintained calibration of controls adjustments damage from improper cleaning and water damage to controls Equipment that has not b...

Reviews: