background image

IMMEDIATELY INSPECT FOR SHIPPING DAMAGE 

All containers should be examined for damage before and during unloading. The freight carrier has assumed 
responsibility for its safe transit and delivery. If equipment is received damaged, either apparent or concealed, a 
claim must be made with the delivering carrier. 

A)  Apparent damage or loss must be noted on the freight bill at the time of delivery. It must then be signed by 

the carrier representative (Driver). If this is not done, the carrier may refuse the claim. The carrier can 
supply the necessary forms. 

B)  Concealed damage or loss if not apparent until after equipment is uncrated, a request for inspection must 

be made to the carrier within 15 days. The carrier should arrange an inspection. Be certain to hold all 
contents and packaging material. 

Installation and start-up should be performed by a qualified installer who thoroughly read, understands and 
follows these instructions. 

If you have questions concerning the installation, operation, maintenance or service of this product, write 
Technical Service Department APW Wyott, 1307 N Watters Rd # 180, Allen, TX 75013. 

SAFETY PRECAUTIONS 

 

Before installing and operating this equipment be sure everyone involved in its operation is fully trained and is 
aware of all precautions. Accidents & problems can result by a failure to follow fundamental rules and 
precautions. 

The following words and symbols, found in this manual, alert you to hazards to the operator, service personnel 
or the equipment. The words are defined as follows: 

 

DANGER:

 This symbol warns of imminent hazard which will result in serious injury or 

death. 

 

 

 

WARNING:

 This symbol refers to a potential hazard or unsafe practice, which could result 

in serious injury or death. 

 

 

 

CAUTION:

 This symbol refers to a potential hazard or unsafe practice, which may result 

in minor or moderate injury or product or property damage. 

 

 

 

NOTICE:

 This symbol refers to information that needs special attention or must be fully 

understood even though not dangerous. 

 

 

 

 

 

NOTICE:

 This product is intended for commercial use only. Not for household use. 

 

 

 

CAUTION:

 These models are designed, built, and sold for commercial use. If these 

models are positioned so the general public can use the equipment make sure that 
cautions, warnings, and operating instructions are clearly posted near each unit so that 
anyone using the equipment will use it correctly and not injure themselves or harm the 
equipment. 

 

 

 

WARNING:

 Improper installation, operation, service or maintenance can cause property 

damage, injury or death. Read and understand these instructions thoroughly before 
positioning, installing, maintaining or servicing this equipment. 

 

 

Summary of Contents for HMG-2424i

Page 1: ...and liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation o...

Page 2: ...d liquids in the vicinity of this or any other appliance Keep the area free and clear of combustibles See ANZI Z83 14B 1991 NOTICE Instructions to be followed if anyone smells gas should be posted in...

Page 3: ...n is fully trained and is aware of all precautions Accidents problems can result by a failure to follow fundamental rules and precautions The following words and symbols found in this manual alert you...

Page 4: ...Do not slide unit with legs mounted lift if necessary to move unit Pipe threading compound must be resistant to the action of liquefied petroleum gases Caution DO NOT use an open flame to check for l...

Page 5: ...15 437 392 1 4 32 000 9 78 128 000 37 5 5 12 4 HMG 2460i 59 844 1520 0 24 609 6 15 437 392 1 5 32 000 9 78 160 000 46 9 5 12 4 HMG 2472i 71 844 1824 8 24 609 6 15 437 392 1 6 32 000 9 78 192 000 56 3...

Page 6: ...With the front panel removed remove the plug from the manifold Place a fitting in the plug opening and connect a manometer For Natural gas the pressure in the manifold should be 5 water column or 12 4...

Page 7: ...7 which may accumulate around this cap The openings must remain open for the regulator to function Clean more often in a very greasy atmosphere...

Page 8: ...rates and light the pilot from above 4 Turn the manual shut off valve on 5 Hold an ignition source match to both openings on the pilot tube When the flames are established remove the ignition source 6...

Page 9: ...act as the heart of the ventilating system for the room or area in which the unit is installed and will leave the unit independent of changing draft conditions All valves must be checked and lubricate...

Page 10: ...ved After removal of the detergent the surface of the plate should then be covered with a thin film of oil to prevent rusting Clean stainless surfaces with a damp cloth and polish with a soft dry clot...

Page 11: ...ing into steam Food sticks to griddle Heat is set too high Griddle surface needs cleaning and or seasoning Surface under food may not have been covered with enough cooking oil Food burned around edges...

Page 12: ...94 Weldm t Griddle Plate 1 22241614 Weldm t Griddle Plate 1 22241734 Weldm t Griddle Plate 1 2 21826433 Side Firebox 2 2 2 2 2 3 21826022 Body 24 Firebox 1 21826122 Body 36 Firebox 1 21826222 Body 48...

Page 13: ...652 Panel Back 36 1 21826252 Panel Back 48 1 21826332 Panel Back 60 1 21826452 Panel Back 72 1 20 22241253 Panel Control 24 1 22241373 Panel Control 36 1 22241493 Panel Control 48 1 22241613 Panel Con...

Page 14: ...2 3 21826036 Body 24 Firebox 1 21826136 Body 36 Firebox 1 21826236 Body 48 Firebox 1 21826336 Body 60 Firebox 1 21826436 Body 72 Firebox 1 4 21826017 Support Bumer 2 21826117 Support Bumer 2 21826217...

Page 15: ...D Shaft 2 3 4 5 6 25 8633700 Leg 2 Dia Hvy Dty 4 4 4 4 4 26 2065839 Adapter 15 Angle Elbow 2 3 4 5 6 27 22400003 Brace Leg 2 2 2 2 2 28 21826134 Channel Stiffiner NA 1 21826234 Channel Stiffiner 1 21...

Page 16: ...16 NOTES...

Page 17: ...17 NOTES...

Page 18: ...e conclusion of this warranty period portable units must be taken to or sent prepaid to the APW Wyott Authorized Service Agency for in warranty repairs No mileage or travel charges are allowed on port...

Reviews: