background image

2.  Loosen the screws on the front of the burner and adjust the air shutter to just eliminate the yellow tips of the 

burner flame. Lock the air shutter in place by tightening the screws. 

 

European Community 

If adjustment becomes necessary in the field, it should be done by a factory authorized and trained technician 
who should seal the screw after the adjustment to safeguard against unauthorized tampering by the end user. 

All burners are lit from constantly burning pilots. Turning the thermostat to the desired temperature is all that is 
required to put the unit in service. 

Do not permit fans to blow directly at the unit. Wherever possible, avoid open windows next to the units' sides 
or back.  Avoid wall type fans which create air cross-currents within a room. 

It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount of air 
removed by any ventilating system. Otherwise, a subnormal atmospheric pressure will occur, which will effect 
operation and cause undesirable working conditions. 

A properly designed and installed hood will act as the heart of the ventilating system for the room or area in 
which the unit is installed and will leave the unit independent of changing draft conditions. 

All valves must be checked and lubricated periodically. This must be done by an authorized service 
representative in your area. 

 

OPERATING INSTRUCTIONS 

 

Season Griddle: 

Heat to low temperature (300-350F/150-180C) and pour on a small amount of cooking oil, about one ounce 
(30cc) per square foot of surface. Spread the oil over the entire griddle surface with a cloth to create a thin film. 
Wipe off any excess oil with a cloth. Repeat this procedure 2 to 3 times until the griddle has a slick, mirror-like 
surface. 

Operation: 

Turn the burners on about 15-20 minutes before cooking for preheating. Set the knobs to the desired 
temperature (HDTG). Each valve will control the gas flow to the burner to bring that area of the plate up to the 
set temperature. If different temperature settings are to be used, adjoining areas should be set at progressively 
higher temperatures using the lowest temperatures on the outside burners. A uniform and systematic approach 
to the loading of the griddle will produce the most consistent product results. 

 

CAUTION:

 Do not turn on gas valves without lighting pilots. This could cause a build up of 

gas and potential explosion. 

 

 

 

NOTICE:

 Due to heat transfer thru the griddle plate, adjoining zones can be no more than 

25° different. 

 

 

 

 

 

Summary of Contents for HTG-2424i

Page 1: ...rs and liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation...

Page 2: ...and liquids in the vicinity of this or any other appliance Keep the area free and clear of combustibles See ANZI Z83 14B 1991 NOTICE Instructions to be followed if anyone smells gas should be posted i...

Page 3: ...eration is fully trained and is aware of all precautions Accidents problems can result by a failure to follow fundamental rules and precautions The following words and symbols found in this manual ale...

Page 4: ...g Do not slide unit with legs mounted lift if necessary to move unit Pipe threading compound must be resistant to the action of liquefied petroleum gases Caution DO NOT use an open flame to check for...

Page 5: ...437 392 1 4 32 000 9 78 128 000 37 5 5 12 4 HTG 2460i 59 844 1520 0 24 609 6 15 437 392 1 5 32 000 9 78 160 000 46 9 5 12 4 HTG 2472i 71 844 1824 8 24 609 6 15 437 392 1 6 32 000 9 78 192 000 56 3 5...

Page 6: ...ith the front panel removed remove the plug from the manifold Place a fitting in the plug opening and connect a manometer For Natural gas the pressure in the manifold should be 5 water column or 12 4...

Page 7: ...liable ignition of the burners when the knobs are turned to HI RELIGHTING PILOT If the pilot light should go out for any reason Promptly shut off all gas at the manual shut off valve Turn off all knob...

Page 8: ...ea in which the unit is installed and will leave the unit independent of changing draft conditions All valves must be checked and lubricated periodically This must be done by an authorized service rep...

Page 9: ...ved After removal of the detergent the surface of the plate should then be covered with a thin film of oil to prevent rusting Clean stainless surfaces with a damp cloth and polish with a soft dry clot...

Page 10: ...ing into steam Food sticks to griddle Heat is set too high Griddle surface needs cleaning and or seasoning Surface under food may not have been covered with enough cooking oil Food burned around edges...

Page 11: ...t Griddle Plate 1 2 21826433 Side Firebox 2 2 2 2 2 3 21831222 Body 24 Firebox 1 21831322 Body 36 Firebox 1 21826722 Body 48 Firebox 1 21826822 Body 60 Firebox 1 21826922 Body 72 Firebox 1 4 21826017...

Page 12: ...NPT Male 4 6 8 10 12 22 2092614 Elbow 3 8c x 3 8 27 Brass 2 3 4 5 6 23 2425310 Pan Grease 24 1 1 1 1 1 24 8706315 Knob Metal Cookline 272 D Shaft 2 3 4 5 6 25 1018064 Insulation Thermostat Bulb 2 3 4...

Page 13: ...21826722 Body 48 Firebox 1 21826822 Body 60 Firebox 1 21826922 Body 72 Firebox 1 4 21826017 Support Bumer 2 21826117 Support Bumer 2 21826217 Support Bumer 2 21826317 Support Bumer 2 21826417 Support...

Page 14: ...21831346 Tube Manifold Onfice Short 1 2 3 4 5 21831246 Tube Manifold Orifice Long 1 NA NA NA NA 31 21831348 Tube Manifold Orifice Long NA 1 1 1 1 32 8834910 Decal Dial Plate T Static Griddles 2 3 4 5...

Page 15: ...Pilot Supply CE 1 21830813 Tube Pilot Supply CE 1 21831512 Tube Pilot Supply CE 1 1 60 21831317 Tube Pilot Supply CE 1 21831513 Tube Pilot Supply CE 1 21832913 Tube Pilot Supply CE 1 21833017 Tube Pil...

Page 16: ...16 NOTES...

Page 17: ...e conclusion of this warranty period portable units must be taken to or sent prepaid to the APW Wyott Authorized Service Agency for in warranty repairs No mileage or travel charges are allowed on port...

Reviews: