One Year Limited Warranty

 

 

Aqua 9+ Beverage Co. Warrants it’s Aqua 9+ Natural Ionic Alkaline Water System to be 
free  from  defects  in  materials  and  workmanship  under  normal  use  for  a  period  of  one 
year from the date of purchase. Aqua 9+ Beverage Co. will repair or replace any part of the 
system  with  the  exception  of  filters  and  membrane.  The  RO  membrane  carries  a  1  year 
warranty.

 

 

CONDITIONS OF WARRANTY

 

 

The  above  warranty  shall  not  apply  to  any  part  of  the Aqua  9+  Beverage  Co.  Alkaline 
water  System  that  is  damaged  because  of  neglect  ,  misuse,  alteration,  accident, 
misapplication,  physical  damage,  fouling,  and  /or  scalding  of  membrane  by  minerals, 
bacterial attack, sediment or damage caused by re, freezing, hot water, or an act of God.

 

Aqua 9+ Beverage Co. assumes no warranty liability in connection with this Natural Ionic 
Alkaline system other than as specified herein.

 

 

WARRANTY SERVICE

 

Warranty  service  will  be  provided  by  Aqua  9+  Beverage  Co.  under  the  following 
conditions:

 

1)

 

Contact  your  local  dealer  who  will  obtain  return  authorization  instructions  from 

Aqua  9+ 

Beverage Co. 

 

2)

 

Ship  unit or part (freight prepaid) to 

Aqua 9+ Beverage Co. 

for warranty evaluation  or 

service. Unit must be returned in original carton or packaged to prevent possible damage. 
Systems or  parts  covered  under  the  warranty  shall  be  repaired  or  replaced  and  returned 
without charge.

 

 

CONDITIONS FOR OPERATION

 

 

 

 

 

Chemical Perimeters - TFC

 

Hardness

 

<350 mg/L (<20 gpg)

 

Iron ( Fe )

 

<0.1 mg/L

 

Manganese ( MN )

 

<0.05 mg/L

 

Hydrogen Sulfide (H S)

 

0.00 mg/L

 

Chlorine ( CL )

 

0.00 mg/L

 

 
 

Source Water Supply - TFC

 

Community / Private

 

Non - Chlorinated

 

System Pressure

 

30 - 100 psi

 

Temperature

 

4 - 38 C ( 40 - 100 F )

 

pH range

 

3.0 - 11.0

 

Max supply TDS level

 

2000 mg/L

 

Turbidity

 

< 1.0 net turbidity (NTU)

 

 

Summary of Contents for AQ9-200GPD

Page 1: ...INSTALLATION MANUAL Natural Ionic Calcium Alkaline Water System AQ9 50GPD AQ9 200GPD AQ9 300GPD MADE IN THE U S A www aquanineplus com...

Page 2: ...terials and rust It will also remove the unpleasant orders of chlorine that was used as a disinfectant and heavy chlorine by products such as chloramines THM and TCE Stage 3 Post Carbon The two carbon...

Page 3: ...rom the water kept in the stor age tank This is the final treatment before drinking the natural ionic calcium alkaline water Stage 9 Ultra Violet Light optional UV light kills 99 99 of bacteria and vi...

Page 4: ...r installation Figure below shows the system interconnection 1 RED LINE Connect from system to feed adapter 2 BLUE LINE Connect from system onto threaded faucet shank with compression nut supplied wit...

Page 5: ...nd the faucet DRAIN CLAMP INSTALLATION 1 The drain clamp should be installed above the trap and on the vertical or horizontal tailpiece see figure 2 2 The hole position on the pipe should be marked an...

Page 6: ...ter System 6 Copyright Aqua 9 Beverage Drain Tube Yellow Tube from RO Drain Saddle Figure 4 Drain Clamp Connection Drain Tube Drain Saddle Figure 3 Drain Clamp Drill Mount Drain Saddle on either locat...

Page 7: ...slowly through the porcelain portion of the sink so that chip ping is cut down to minimum MOUNTING THE FAUCET 1 Disassemble the bottom portion of the faucet 2 Place into hole of sink and reassemble f...

Page 8: ...ere it would cause damage if failure or leakage occurred 1 Prior to installation the feed water assembly please assure that the following water conditions are met Feed water conditions Min Max Inlet p...

Page 9: ...ed adapter and tighten Solid copper riser tube same procedure as ex tubing except you must cut out a piece of the riser tube about 3 4 to 1 so the hex feed adapter can fit be tween faucet and riser tu...

Page 10: ...is mem brane and should be changed at the same time with the pre filter 3 The post filters should be changed when you experience an unusual taste and or order to the water and it has a normal life bet...

Page 11: ...96 98 Mercury 94 97 Hardness Ca Mg 93 97 Radioactivity 93 97 Uranium 96 Chloride 92 95 Ammonium 80 90 Bromide 90 95 Phosphate 95 98 Cyanide 85 95 Sulfate 96 98 Thiosulfate 96 98 Silicate 92 95 Silica...

Page 12: ...warranty liability in connection with this Natural Ionic Alkaline system other than as specified herein WARRANTY SERVICE Warranty service will be provided by Aqua 9 Beverage Co under the following co...

Reviews: