7. Installation of the PC interface circuit board
Install the circuit board in a free slot of your case. The slot does not
have to have any connection on the mainboard.
Two jumpers are available on the circuit board. A single jumper is con-
tained in the scope of delivery which must be used for the correct func-
tion of the aquaduct like described in the following! Two openings by
which the water hoses can be led into the inside of the PC are drilled in
the slot metal. To prevent damages to the tubes, rubber rings are pre-
assembled in the openings.
7.1. FAN_JUMPER
Has to be set only for aquaduct variants with 115 or 230 V pumps!
With this jumper you can select
whether the
fans shall be powered
with
5 or 12 V. The jumper must always be set on the middle pin and an
outer pin. If the jumper is removed, the the
fans
are turned off com-
pletely. In this case it is highly recommend to check the temperature of
the system constantly as the system will eventually overheat!
© 2007
Aqua Computer GmbH & Co. KG
- 17 -
Gelliehäuser Str. 1, 37130 Gleichen