AQUA CREEK PRODUCTS
24V SPA/PRO SPA LIFT TROUBLESHOOTING GUIDE
Before troubleshooting make sure the battery is fully charged.
If the lift doesn’t move when the handset button is pressed:
When you can’t get the lift to move check the following things:
1.
Make sure the battery is fully charged:
A. Before charging the battery first make sure the
green
light on the front of the charger is
illuminated (this means that the charger is on). Then check to make sure the silver contact points
on the battery and charger are not damaged or corroded, and that they are clean. Then place the
battery on the charger and look for the
orange
charge light to illuminate on the front of the
charger. When the orange light goes off the battery is fully charged.
B. When the battery is correctly installed on the charger or control box you should hear a “click”
indicating the battery is properly seated on the unit. Also note that when the battery is properly
seated there should not be any gaps between the battery and the control box/charger.
The top
green light
will always be
illuminated indicating that it has
power. When charging the battery the
bottom
orange light
will illuminate,
until fully charged.
Not attached properly.
Note the
white bracket is in front of silver clip,
which will not allow for an electrical
connection.
Properly Attached.
Note that the white bracket is behind the
silver clip. Not allowing movement.