I. Connect hose connector to portal marked “UPFLOW INLET” and flush for 10 minutes or
un:l water becomes clear. The tank is now ready for installa:on.
J. Disconnect the hose from the connector then remove connector from the tank and
keep for future use.
How do I switch my pool from salt water to fresh water?
1. Connect the Aqua-Excellence Pool Sani:zer and De-Chlorinator to your pool by
following the provided pool installa:on process. The salt water will not damage the
sanita:on system.
2. It is not recommended to drain your pool as it may cause damage by making it “float”
up from the ground.
3. The salt will naturally dissipate over :me by water being introduced because of
evapora:on, and rainfall.
4. One op:on to remove salt is to aoach the Aqua-Excellence Pool Sani:zer and De-
chlorinator and allow the salt cell to con:nue to run for approximately one (1) week.
If this method is used do not place a chlorine tablet in the skimmer as it may introduce
too much chlorine along with the salt system salt cell/chlorine generator and too much
chlorine may affect the PH level. The salt cell or chlorine generator will con:nue to
deplete the salt from the system as it generates chlorine. Aner this one week period,
disconnect/detach the salt cell and place a 2”-3” chlorine tablet into the skimmer
basket to oxygenate dead bacteria, so it will catch in the filter. Any remaining salt will
eventually dissipate.
Will My Current Pool Filter Work?
The Aqua-Excellence Pool Sani:zer and De-Chlorinator will work with all types of filters.
Sand filters are the quickest and easiest as they are simply backwashed approximately once a
week. Cartridge filters may allow debris to pass by as the filter is being removed. For this
reason, the sanita:on system bypass should be ac:vated just prior to cartridge-filter changes
then deac:vated aner flushing the system once the filter housing is assembled. Cartridge type
filters may begin to deteriorate aner a year. If the cartridge filter does show signs of
deteriora:on, it should be replaced to avoid clogging the sanita:on system.