IMPORTANT SAFETY INSTRUCTIONS
This guide provides installation and operation instructions for this pump. Consult your supplier
with any questions regarding this equipment.
1.1 When installing and using this electrical equipment, basic safety precautions should
always be followed:
•RISK OF ELECTRICAL SHOCK. Connect only to a branch circuit protected by a ground-fault
circuit-interrupter (GFCI). Contact a qualified electrician if you cannot verify that the circuit is
protected by a GFCI.
•This pump is for use with permanent installed in ground or above ground swimming pools and
may also be used with hot tubs and spas if so marked. Do not use with above ground pools
that can be readily disassembled for storage.
• The pump is not submersible.
• Before servicing the pump; switch off power to the pump by disconnecting the main circuit to
the pump.
• Never open the inside of the drive motor enclosure.
1.2 All installations must be fitted with earth leakage or residual current protection
devices, having a rated residual operating current not exceeding 30mA.
WARNING:
• Do not run the pump dry. In case of dry run, mechanical seal will be damaged and the pump
will start leaking. Fill the pump with water before starting.
• Before servicing the pump, switch OFF power to the pump by disconnecting the main circuit
to the pump and release all pressure from pump and piping system.
• Never tighten or loosen screws while the pump is operating.
• Do not block the pump suction.
2. TECHNICAL SPECIFICATIONS
Model
Advised pool
volume
(m³)
P1
Voltage/Ph
Current
Backwash
Circulation
kw
A
Qmax
Hmax
at 6m
at 8m
at 10m
GFVS19N
40~80
0.13~1.0
220-240/1
1.30~7.29
33.7
21
8.16~24
8.5~20.5 7.1~16.3