ENGLISH
42
1- User panel cover
2- User panel
3- QR code
4- Quick guide
5- Terminal board cover
6- External connector
7-
Power cable inlet
Figure 2
1.2 Technical characteristics
The technical characteristics are summed up in the table below.
Topic
Parameter
PRIME E-SILENCE VS
ELECTRIC POWER
SUPPLY
Voltage
220-240 V +/- 10%
Frequency
50/60 Hz
Maximum current
5.6 SFA
Maximum power
1250 W
CONSTRUCTION
CHARACTERISTICS
Overall dimensions 550 x 300 x 316 mm / 22.6 x 12.2 x 12.4 in
Empty weight
(excluding
packaging)
18 kg / 39 lb
Protection class
IP55
Motor insulation
class
F
HYDRAULIC
PERFORMANCE
Maximum head
16 m / 52 ft
Maximum flow rate
32 m3/h / 141 gpm
Maximum working
pressure
2,5 bar
WORKING
CONDITIONS
Max liquid
temperature
40°C / 104°F
Max ambient
temperature
50°C / 122°F
Table 1 – Technical Characteristics
1.3 SVRS Notes (Only applicable to model SVRS)
The Safety Vacuum Release System (SVRS) model is designed to provide an additional layer of protection against body
suction entrapment. It complies with ASME/ANSI A112.19.17 -2010 SVRS standard.
1. SVRS devices shall only be installed in conjunction with an ASME A112.19.8 suction fitting, or a 12 in. x 12 in. (305
mm x 305 mm) drain grate or larger, or an approved channel drain system at each suction outlet or drain outlet.
2. Check valves and hydrostatic valves shall not be used in suction systems protected by SVRS devices.