2.5 Electrical connections for auxiliary inputs and outputs
The pump has a connector for configurable user inputs and outputs.
The following figure shows the connector contacts, while the table below sums up the associated signals:
Figure 4
PIN NAME
Wire Color SIGNAL DESCRIPTION
1
IN0_D
RED
Digital Input 0 (start/stop)
2
IN0_A
BROWN
Analog Input 0 (0-10V or 4-20mA)
3
GND
BLACK
Earth
4
OUT COM
BLUE
Output relay: Common Contact
5
OUT NO
WHITE
Output relay: Contact Normally Open
6
IN1_D
PINK
Digital Input 1
7
IN2_D
GREEN
Digital Input 2
8
IN3_D
YELLOW
Digital Input 3
9
OUT NC
VIOLET
Output relay: Contact Normally Closed
10
GND
GREY
Earth
11
IN4_D
RED/BLUE Digital Input 4
12
N.U.
PINK/GREY Not used
2.5.1 Inputs
The auxiliary inputs can be configured for different types of control:
1) Digital/analog control:
PIN 1:
digital input, clean contact (maximum voltage 5Vdc, maximum current 1mA); the contact is configurable if
normally closed or open (see par. 5.7 “INPUT TYPE”)
PIN 2:
An input for an external analog signal, configurable as 0-10V or 4-20 mA .
PIN 3:
Earth contact for the connection of all inputs.
The following figure shows the relationship between the analog signal on input and the setpointSP to be activated.