UNIT OF MEASURE
PARAMETERS VALUES
DESCRIPTION
Head H
m (metri)
ft (feet)
Sets the unit of measure for the
Head
Flow Q
m3/h
US GPM
l/min
Sets the unit of measure for the
Flow rate
Temperature
°C
°F
Sets the unit of measure for the
Temperature
PUMP LIMITS
PARAMETERS VALUES
DESCRIPTION
Head Hmax
PRIME E-
SILENCE VS
5 m - 16 m
MAX
If the system is not able to bear
pressures or flows that are too high,
it is possible to impose maximum
limits on the pump control.
Flow Qmax
PRIME E-
SILENCE VS
10 m3/h - 30
m
3
/h
Note: if the upper limits H
max
and Q
max
are set at values lower
than “MAX”, it is possible to set the setpoints even at values
larger than the limits; however, during activation these upper
limits will never be exceeded (self-limitation of the system) and the
setpoints may not be reached.
SVRS (only for models with SVRS)
PARAMETERS VALUES
DESCRIPTION
Restarting
Auto
Enables AUTOMATIC restart after
stopping for SVRS protection.
Manual reset with the "RESET"
button is always enabled.
Manual
Allows only manual restart with the
"RESET" button after stopping for
SVRS protection.
Disabling time
1 min-60
Sets the temporary deactivation
time. Useful for cleaning the pool
with Hydraulic Cleaners.
SVRS
enable/disable
Pressing the "ENTER" key
temporarily disables the function. A
countdown shows the time still
available before the SVRS is
automatically enabled.
Before starting the pump with SVRS disabled, always check that there is no one in the pool.
For example, by pressing the QuickClean button you can now start the pump without the SVRS being able to trip.
When the pump is running, the inactive SVRS condition is indicated by the flashing of the red alarm LED ( ) (fault)
and by a flashing message on the display (homepage).
ADJUSTING THE VISOR
PARAMETERS VALUES
DESCRIPTION
Backlight
0-100%
Backlight
Sleep Time
20 sec - 10 m /
always
When the backlight is off, the first
time any key is pressed has the
sole effect of restoring the
backlighting.