5.8 SYSTEM Menu
SYSTEM
This menu item groups together a number of pages for the advanced user.
Sub-Menu
DESCRIPTION
Info
Information on operating status, totals and
statistics (operating hours, pumped volume,
energy consumption) and other data (such as
firmware version, serial number). The totals and
statistics shown are overall and partial; the
partial totals can be reset (Reset) by the user
(by holding down “OK” [] for 3 seconds, as
indicated on the display).
Sub-Menu
DESCRIPTION
Factory settings
Resets the factory settings (see also paragraph
7.1).
Sub-Menu
DESCRIPTION
Updating
Allows updating of the product firmware, which
can be done via wireless using the appropriate
device "DAB E.sylink".
6 PROTECTION SYSTEMS – LOCKS (FAULT)
The device is equipped with protection systems to preserve the pump, the motor, the supply line and the inverter. If one
or more protections trip, the one with the highest priority is immediately notified on the display.
Faults cause switching off of the motor and lighting of the red warning LED ( ).
In some types of fault, the motor restarts as soon as normal conditions are restored; in others, attempts at automatic
reset are carried out after a certain space of time.
It is also possible to try to cancel the error condition manually (see the following paragraphs).
If the error condition remains, you must take steps to eliminate the cause of the fault.
In system fault condition, with the red LED ( ) lit, the keys “SET1-4” or “QuickClean” are not accepted;
however, if one them is already active, it remains.
Fault
No.
Description on the display
e1 / e14 Internal error
e15
Motor phases short circuit
e16
Short circuit to earth
e17 / e19 Internal error
e20 / e22 Electronic excess temperature
e23
Low mains voltage
e24
High mains voltage
e25
Motor excess temperature
e26
Motor blocked
e27
Dry operation
e28
Pump not primed
e29
No current
e31
Internal error
Table 5 – List of Faults