3
recommend that a valve, elbow or tee installed in the suction line should be no closer to the
front of the pump than five times the suction line diameter.
4.3. Valves and Fittings
1). Do not install 90° elbows directly into pump inlet. Elbows should be no closer than 250mm
to the inlet. Joints must be tight. Suction line diameter must equal or be larger than the
discharge line diameter.
2). Flooded suction systems should have gate valves installed on suction and discharge pipes
for maintenance, however, the suction gate valve should be no closer than five times the
suction pipe diameter as described in this section.
3). Use a check valve in the discharge line when using this pump for any application where
there is significant height to the plumbing after the pump.
4). Be sure to install check valves when plumbing in parallel with another pump. This helps
prevent reverse rotation of the impeller and motor.
5. SETTING & OPERATION
5.1 Interface
Manual Mode
Timer Mode
Description
On/off
Lock/Mode: When the screen is unlocked, this
button is for manual setting and speed selection.
While the screen is locked, this button is for
unlocking the screen.
Up: Increase value(speed & time)
Down: Decrease value(speed & time)
Timer: Switching from manual to Timer mode
ELBOW
250mm
Suction
40/50mm
Return to pool 40/50mm