© 2008 Aqua-Hot
®
600-D Hydronic Heating System Installation Manual
— Page 22 —
section 5: switch Panel
Switch Panel Location:
Select a location in the interior of the coach that allows
for easy operator access.
All electric installations, systems, and equipment
shall comply with Article 551, Parts I and III through
VI of NFPA 70, as well as the regulation of authorities
having jurisdiction and CSA Standard B139.
Figure 30
Switch Panel Mounting:
1.
Cut out an opening for the switch panel plate. The
Aqua-Hot 600-D requires a 5 inch W x 1.25 inch H
opening. Reference Figure 30.
2.
Once the switch panel has been completely wired, per-
manently mount the switch panel in place. Reference
Figure 30.
3.
Move all switches to their
OFF
position by pressing
them in a downward motion.
.150 (4X)
2.33
6.43
5.88
4.95
2.88
1.205
.80
.28
.28
.74
.871 (4x)
1.36
2.72
4.08
Summary of Contents for 600-D
Page 1: ...2008 Aqua Hot Heating Systems Inc Installation Manual...
Page 43: ...Appendix B Appendix B Wire Gauge Information...
Page 45: ...Appendix C Appendix C Electronic Controller Features...
Page 48: ...Appendix D Appendix D Antifreeze Types...
Page 50: ...Appendix E Appendix E Antifreeze Mixture Water Quality Recommendations...
Page 52: ...Appendix F Appendix F Antifreeze Terms and Mixture Ratio...