aqua-Hot Hydronic Heating system
Diesel-Burner, Heat Input (Firing Rate) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56,000 BTU/hr.
Diesel-Burner, Fuel Consumption (Continuous Operation) . . . . . . . . . . . . . . . . 0.40 gal/hr.
Heater, Voltage/Maximum Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . 12 Volt-DC/60 watts
Electric Heating Element specifications
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (2) 120 Volt-AC/2000 watts
Zone Heat Circulation Pump specifications
. . . . . . . . . . . . . . . . . . . . . . . . . . . . (3) 12 Volt-DC/21 watts each
Number of Heating Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . maximum of 5, plus Engine Preheat
Domestic Water Heating Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . continuous/on-demand
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18.5”H x 18.5”W x 36.75”L
Dry Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . approximately 186 lbs.
Wet Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . approximately 303 lbs.
Figure 1
© 2008 Aqua-Hot
®
600-D Hydronic Heating System Installation Manual
Summary of Contents for 600-D
Page 1: ...2008 Aqua Hot Heating Systems Inc Installation Manual...
Page 43: ...Appendix B Appendix B Wire Gauge Information...
Page 45: ...Appendix C Appendix C Electronic Controller Features...
Page 48: ...Appendix D Appendix D Antifreeze Types...
Page 50: ...Appendix E Appendix E Antifreeze Mixture Water Quality Recommendations...
Page 52: ...Appendix F Appendix F Antifreeze Terms and Mixture Ratio...