SPECIFICATIONS
Probe Range:
PTC:
-58 to 302°F (-50 to 150°C).
Input:
PTC 1000 Ω @ 77
°
F
(
25°C)
Control Type:
On/Off.
Power Requirements:
90 to 255 VAC 50 / 60 Hz (±10%)
Power Consumption:
3.6VA.
Accuracy:
±1% Full Scale.
Display:
3 digits plus sign.
Resolution:
1° ≥ 100°.
Memory Backup:
Non-volatile memory.
Ambient Temperature:
32 to 104°F (0 to 40°C).
Weight:
2.5 lbs (1134 g).
Front Protection:
NEMA 4X (IP66).
Agency Approvals:
CE, UL, cUL.
Controller power rating by model number.
Model
Volts / PH
Maximum Chiller size HP or
Maximum Heater size Watts
DC115S
115 / 1
Up to -1/2 or 1200
DC115S-20
115 / 1
Up to -3/4 or 1800
DC230S
230 / 1
Up to 1-1/2 or 2000
Display Calibration and Program Parameters
If the displayed water temperature on the control is different from the
system water temperature, than an adjustment to the control can be
done. The easiest way to calibrate the control is to press and hold the
"Set" button for 8 seconds. The parameter “O” will be displayed. Wait
4 seconds. Then press the “SET” button and the “SP” will be
displayed. Use the down
▼ or up ▲ arrow until you see the menu
parameter "P1". Then press the “SET” button one time. The display
will show “0”. Press the up or down arrows to adjust to the
temperature offset. Once you have set the correct temperature offset,
press "SET" button one more time and then wait 1 minute or press
the “SET” and the “DOWN”
▼ arrow buttons at the same time to quit
the programming. The display should return to the water temperature.
The display should read correct water temperature readout.
See page 3 ”DC SINGLE STAGE TEMPERATURE CONTROL
PROGRAMMABLE PARAMETERS TABLE” to change other settings
To adjust other parameters in the control contact Aqua Logic, Inc. for
help.
PH: 858.292.4773 or email: info@aqualogicinc.com
5
2