SPECIFICATIONS 
 

Probe Range: 
PTC: 

-58 to 302°F (-50 to 150°C). 

Input: 

PTC 1000 Ω @ 77

°

F

 (

25°C) 

Control Type: 

On/Off. 

Power Requirements: 

90 to 255 VAC 50 / 60 Hz (±10%) 

Power Consumption: 

3.6VA. 

Accuracy: 

±1% Full Scale. 

Display: 

3 digits plus sign. 

Resolution: 

1° ≥ 100°. 

Memory Backup: 

Non-volatile memory. 

Ambient Temperature: 

32 to 104°F (0 to 40°C). 

Weight: 

2.5 lbs (1134 g). 

Front Protection: 

NEMA 4X (IP66). 

Agency Approvals: 

CE, UL, cUL. 

Controller power rating by model number. 

Model 

Volts / PH 

Maximum Chiller size HP or 

Maximum Heater size Watts 

DC115S 

115 / 1 

Up to -1/2  or   1200 

DC115S-20 

115 / 1 

Up to -3/4   or   1800 

DC230S 

230 / 1 

Up to 1-1/2  or  2000 

 

 

 

 

Display Calibration and Program Parameters  

If the displayed water temperature on the control is different from the 
system water temperature, than an adjustment to the control can be 
done. The easiest way to calibrate the control is to press and hold the 
"Set" button for 8 seconds. The parameter “O” will be displayed. Wait 
4 seconds. Then press the “SET” button and the “SP” will be 
displayed. Use the down 

▼ or up ▲ arrow until you see the menu 

parameter "P1". Then press the “SET” button one time. The display 
will show “0”. Press the up or down arrows to adjust to the 
temperature offset. Once you have set the correct temperature offset, 
press "SET" button one more time and then wait 1 minute or press 
the “SET” and the “DOWN” 

▼ arrow buttons at the same time to quit 

the programming. The display should return to the water temperature. 
The display should read correct water temperature readout.  

 

See page 3 ”DC SINGLE STAGE TEMPERATURE CONTROL 
PROGRAMMABLE PARAMETERS TABLE” to change other settings 

 

To adjust other parameters in the control contact Aqua Logic, Inc. for 
help. 

PH: 858.292.4773  or email: info@aqualogicinc.com 

 