DC SINGLE STAGE TEMPERATURE CONTROL 
PROGRAMMABLE PARAMETERS TABLE 

Parr. 

Description 

Units 

Range 

Factory 

Settings 

Note 

Change 

 1  SP1  Set Point 

Degrees  r1 to r6 

75 

 

r0 

Differential / Hysteresis 

Degrees  1 to 20° 

 

r1 

Lower value set point 

Degrees  -50 to 150 °C 

-50 to 302 °F 

30°F 

 

r2 

Higher value set point 

Degrees 

-50 to 150 °C 
-50 to 302 °F 

100°F 

 

d0 

Heating or Cooling 

Option 

Ht or Co 

Co 

 

d2 

Time for Defrosting 

Minutes  0 to 59 

 

d8 

Interval Time between 
Defrosts 

Hours 

0 to 24 

 

c0 

Min. time stop for 
compressor 

Minutes  0 to 59 

 

c1 

Continuous cycle time 

Hours 

0 to 24 

 

10  c2  On time of fault cycle 

Minutes  0 to 99 

 

11  c3  Off time of fault cycle 

Minutes  0 to 99 

 

12 

P0 

Temperature scale 
selection 

Option 

C / 

 

13  P1  Ambient Probe 

Adjustment 

Degrees  -10 to 10° 

 

14  H5  Parameter Access Code   Number  0 to 99 

 

15  H6  Probe input type 

Option 

Ptc / Ntc 

Ptc 

 

16  t0  Max. temperature on 

display 

Degrees  -50 to 150 °C 

-50 to 302 °F 

100°F 

 

 

 

 

 

PARAMETER DESCRIPTIONS 

 

SP = Set Point. 

Temperature desired to regulate the machine. Can vary 

from r1 to r2. 

r0 = Differential. Heating

: If temperature is ≥ SP then output is OFF. If 

temperature is < SP - r0 then output is ON. 

Cooling

: If temperature is ≥ 

SP + r0 then output is ON. If temperature is < SP then output is OFF. 

r1 = Lower Set Point Limit. 
r2 = Upper Set Point Limit. 
d0 = Heat or Cooling Control. 

Ht = heating control, Co = cooling control. 

d2 = Not used

 

d8 = Not used

c0 = Minimum Time for Compressor to be OFF. 

Minimum time for the 

compressor to stop until it can start again. 

c1 = Continuous Cycle Time. 

The remaining time for a continuous cooling 

cycle. 

c2 = ON Time 

of fault cycle, during probe error. 

c3 = OFF Time 

of fault cycle, during probe error. 

P0 = 

Selection of Engineering units between F and C. 

P1 = Ambient Probe Calibration. 

Offsets temperature in degrees to 

adjust the ambient probe. 

H5 = Access Code to Parameters. 

Factory-set to 0. 

H6 = Selection of Input Probe Type: 

PTC or NTC. 

t0 = Temperature Display Limit. 

Maximum temperature shown on the 

display, although the real temperature can be greater. 

OPERATION IN CASE OF ERROR 

If the probe or thermostat memory should fail, the chiller or heater will 
turn off. 

 

Error Messages  

In normal operation, the probe temperature will be shown. In case of 
alarm press the “SET” and the “DOWN” 

▼ arrow buttons at the same 

time to quit the alarm. An error messages will be shown:

 

 

Er

 – Memory error 

 

--

 

Shorted –circuited probe error 

 

oo-

 Open probe 

 

 

 