background image

 

9

 

Fig. 1: Skimmer K1, K2, K3                                                    

 
1.   Reaction pipe 

17. Hose connection pressure side  

2.   Foam cup   

18. O-ring pressure side 

3.   Lid for foam cup                                     

19. Venturi pump  

4.   Silencer 

20. Rubber bearing (20a only valid for K1)       

5.   Hose connection of silencer 

21. Ceramic bearing (21a only valid for K1)       

6.   Adjusting screw 

22. O-ring for pump housing 

7.   Air hose 

23. Seal for pump housing 

8.   Ozone connection (underneath) 

24. O-ring pressure side 

9.   Outlet   

25. (K1) Air suction nozzle K1 

10. Fixing screw       

25. (K2/3) Reduction K2 and K3   

11. Perforated plate   

26. (K1) Connection for air hose K1    

12. O-ring 

26. (K2/3) Air hose connection angle K2/K3 

13. Bottom plate 

27. (K2/3) Union nut pressure side K2/K3 

14. Screw set for bottom plate   

28. Outlet foam cup     

15. Connecting hose  

29. Bottom plate of venturi pump 

16. Union nut pressure side 

30. Aqua Medic Power Wheel 

Summary of Contents for K Series

Page 1: ...t entschieden Es ist speziell für den aquaristischen Gebrauch entwickelt und von Fachleuten erprobt worden Mit diesem Gerät sind Sie bei richtiger Anwendung in der Lage die organischen Inhaltsstoffe Ihres Aquarienwassers wirksam zu entfernen AB Aqua Medic GmbH Gewerbepark 24 49143 Bissendorf Germany __________________________________________________________________________________________ ...

Page 2: ...pakte Bauweise vollständig zerlegbar für leichte Reinigung Version K1 K2 K3 Für Aquariengrößen 100 500 l 200 1 000 l 300 1 500 l Leistungsaufnahme gesamt max 18 Watt max 31 Watt max 58 Watt Pumpe DC Runner K1 DC Runner K2 DC Runner K3 Luftleistung max 1 000 l Std max 1 800 l Std max 3 100 l Std Gesamthöhe ca 45 cm ca 48 cm ca 54 cm Ausbauhöhe Schaumtopf ca 48 cm ca 51 cm ca 57 cm Benötigte Stellfl...

Page 3: ...uftschlauch 24 O Ring Druckseite 8 Ozonanschluss unterseitig 25 K1 Luftansaugdüse K1 9 Auslauf 25 K2 3 Reduktion K2 und K3 10 Befestigungsschraube 26 K1 Anschluss Luftschlauch K1 11 Lochplatte 26 K2 3 Anschlusswinkel Luftschlauch K2 K3 12 O Ring 27 K2 3 Überwurfmutter Druckseite K2 und K3 13 Bodenplatte 28 Ablass Schaumtopf 14 Schraubensatz Bodenplatte 29 Bodenplatte Dispergatorpumpe 15 Verbindung...

Page 4: ...in die Nut gelegt wurden Für optimale Luftleistung und Laufruhe die Pumpe möglichst waagerecht montieren 3 2 Aufbau der Pumpe Die Dispergatorpumpe wird mit einem elektronischen Sicherheitstransformator AC 110 240 V 50 60 HZ und 24 V DC Ausgangsspannung betrieben Zum Öffnen der Pumpe Halteplatte entfernen und den Verschluss des Kreiselgehäuses durch Drehen entriegeln Die Aufstellung hat so zu erfol...

Page 5: ...pumpe auf niedriger Stufe startet Ein zu hoher Durchfluss führt zu einem sehr schnellen Überlaufen des Schaumtopfes Hier ist besondere Vorsicht geboten wenn man die Ablauföffnung des Schaumtopfes über einen Schlauch mit einem neben dem Filterbecken stehenden Behälter verbindet Es besteht die Gefahr dass beim Überkochen des Abschäumers auch der Behälter überläuft Dadurch kommt es außerdem zu starke...

Page 6: ...ehäuse bzw das Power Wheel sind verschmutzt Maßnahme Dispergatorpumpe abmontieren Power Wheel und Pumpe gründlich reinigen Lufteinzugsdüse mit dünnem Stäbchen oder Bürste reinigen und Pumpe wieder anschließen Problem Der Abschäumer schäumt zu stark ab Der Schaumtopf ist zu schnell gefüllt Ursache Der Wasserstand im Filterbecken ist nicht optimal Durchfluss zu hoch Maßnahme Wasserstand korrigieren ...

Page 7: ...mer you have selected a top quality product It has been specifically designed for aquarium use and tested by professionals This unit will effectively remove organic substances from your aquarium water AB Aqua Medic GmbH Gewerbepark 24 49143 Bissendorf Germany __________________________________________________________________________________________ ...

Page 8: ...nually compact design allows for use in small areas can be completely dismantled for easy cleaning Version K 1 K 2 K 3 For aquaria 100 500 l 200 1 000 l 300 1 500 l Total consumption max 18 watts max 31 watts max 58 watts Pump DC Runner K1 DC Runner K2 DC Runner K3 Air power max 1 000 l h max 1 800 l h max 3 100 l h Total height app 45 cm app 48 cm app 54 cm Height foam cup app 48 cm app 51 cm app...

Page 9: ...or pump housing 7 Air hose 23 Seal for pump housing 8 Ozone connection underneath 24 O ring pressure side 9 Outlet 25 K1 Air suction nozzle K1 10 Fixing screw 25 K2 3 Reduction K2 and K3 11 Perforated plate 26 K1 Connection for air hose K1 12 O ring 26 K2 3 Air hose connection angle K2 K3 13 Bottom plate 27 K2 3 Union nut pressure side K2 K3 14 Screw set for bottom plate 28 Outlet foam cup 15 Conn...

Page 10: ... the O rings Fig 1 No 18 24 are placed into the groove If possible mount the pump horizontally for best air power and quiet operation 3 2 Setup of the pump The pump DC Runner is operated by an electronic safety transformer at AC 110 240 V 50 60 Hz and 24 V DC output To open the pump remove retaining plate and release the pump lock by turning it After setting the pump up please ensure you can alway...

Page 11: ...overflowing of the foam cup Here special caution is required if one connects the outflow nozzle of the foam cup via a hose with a container standing beside the filter sump There is the danger that the container overflows if the skimmer spills over Thus this would also lead to strong loss of water in the filter sump whereby other devices could run dry and therefore could be damaged The flow should ...

Page 12: ...fast Cause The water level in the filter sump is not optimal water flow is too quick Action Adjust water level or decrease the pump power 7 Warranty Should any defect in materials or workmanship be found within 24 months of the date of purchase AB Aqua Medic undertakes to repair or at our option replace the defective part free of charge always provided the product has been installed correctly is u...

Page 13: ...eínas usted ha elegido un producto de máxima calidad Ha sido específicamente diseñado para su uso en acuarios y testado por profesionales Esta unidad removerá sustancias orgánicas con eficiencia del agua de su acuario AB Aqua Medic GmbH Gewerbepark 24 49143 Bissendorf Germany __________________________________________________________________________________________ ...

Page 14: ...compacto que permite su uso en áreas pequeñas Se puede desmontar completamente para una fácil limpieza Versión K 1 K 2 K 3 Para acuarios 100 500 l 200 1 000 l 300 1 500 l Consumo total max 18 vatios max 31 vatios max 58 vatios Bomba DC Runner K1 DC Runner K2 DC Runner K3 Caudal de aire max 1 000 l h max 1 800 l h max 3 100 l h Altura total app 45 cm app 48 cm app 54 cm Altura con taza recolectora ...

Page 15: ...bomba 7 Manguera de aire 23 Cierre para cuerpo de la bomba 8 Conexión para ozono debajo 24 Junta lado presión 9 Salida 25 K1 Boquilla para succión de aire K1 10 Tornillo de fijación 25 K2 3 Reducción K2 y K3 11 Plato perforado 26 K1 Conexión para manguera de aire K1 12 Junta 26 K2 3 Codo de conexión para manguera de aire K2 K3 13 Plato de base 27 K2 3 Tuerca de unión lado presión K2 K3 14 Juego de...

Page 16: ... colocadas dentro del surco Si es posible monte la bomba en posición horizontal para una mayor absorción de aire y una operación más silenciosa 3 2 Disposición de la bomba La bomba DC Runner trabaja mediante un transformador electrónico de seguridad a 110 240 V 50 60 Hz y una salida de 24 V DC Para abrir la bomba retire la placa de retención y suelte el bloqueo de la bomba girándolo Después de sit...

Page 17: ...Refill System El skimer se llenará arrancando la bomba venturi a una potencia baja Un flujo de agua muy rápido conduce a un desbordamiento muy rápido de la cazoleta recolectora de espuma Aquí se requiere una precaución especial si se conecta la boquilla de salida de la cazoleta recolectora de espuma a través de una manguera con un contenedor que está al lado del filtro sump Existe el peligro de qu...

Page 18: ... un cepillo suave o un instrumento sin filo y rearme la bomba de nuevo Problema El skimer espuma muy rápidamente La cazoleta se llena muy rápidamente Causa El nivel de agua en el filtro sump no es el óptimo el flujo de agua es demasiado rápido Acción Ajuste el nivel de agua o reduzca la potencia de la bomba 7 Garantía Ante defectos en el material o mano de obra AB Aqua Medic garantiza durante 24 m...