background image

 

3. Theory 
 

Protein skimming is a method of physical water treatment. It uses a phenomenon known from our 
daily experience: the adhesion of surface active substances to air water layers. If we add a drop of 
oil to a water surface, a thin film is produced with a thickness of only one molecule. Surface active 
compounds like proteins behave in the same way. The 

Turboflotor Percula 

uses its air bubbles to 

create  a  large  water  surface  for  the  waste  substances  to  attach  themselves  to.  These  air  bubbles 
are forced into the reactor-pipe in a such a way that they undergo a long contact time within the 
counter current. Enriched with organic substances, they rise to the top and form a firm foam, that 
is  dehydrated  and  pushed  into  the  collection  cup.  This  method  removes  organic  wastes  from  the 
aquarium water before they become part of the biological waste treatment cycle.  

 

The  venturi  pump  of  the

  Turboflotor  Percula

  draws  the  water  out  of  the  aquarium  or  the  filter 

chamber, mixes it in the pump housing with air, which is then cut into small air bubbles by the AB 
Aqua  Medic 

needle  wheel

.  This  water/air  mixture  is  pumped  into  the  reaction  pipe  where  the 

organic substances are taken up by the air bubbles. Foam is formed and is pushed into the foam 
cup. The cleaned water flows to the bottom of the skimmer back into the aquarium or into the filter 
chamber. 

 
4. Set-up 
 

The 

Turboflotor Percula

 designed for the use in the Aqua Medic Percula aquarium. Of course, it 

can  be  used  in  any  other  well  circulated  filter  chamber.  For  use  directly  in  an  aquarium,  the 
skimmer  is  not  recommended,  because  the  maintenance  of  the  pump  may  be  difficult.  In  the 
percula aquarium, the skimmer is just placed in the firts filtration chamber of the filter – and can 
be started. 
 

5. Starting / Performance 
 

The  system  can  be  started  when  the 

Turboflotor

  is  correctly  installed.  After  switching  the  pump 

on, air is automatically drawn into the skimmer. To minimize the noise level, connect the air inlet 
tube with the blue connecting piece of the silencer supplied. Fix the silencer with the holding device 
on the aquarium or the filter system. 
 
The needle wheel breaks the air into small bubbles. This method eliminates the greater proportion 
of the noise. The quantity of drawn air should be adjusted so that 75 % of the reaction pipe is filled 
with  air  bubbles.  After  the  initial  start,  some  hours  may  pass  before  the  first foam  is pushed  into 
the  collection  cup.  This  is  due  to  a  reaction  between  the  surface  of  the  acrylic  glass  and  the 
aquarium  water.  Equilibrium  of  electrical  charges  takes  place.  After  a  maximum  of  24  hours,  the 
foam  should  push  evenly  into  the  collection  cup.  The  quantity  of  liquid  and  organic  substances  is 
dependent on the pollution of the aquarium.  
 

Adjustments: 

Due  to  the  construction,  air  and  water  mixing  is  automatic  and  no  adjustment  is 

required.  It  is,  however,  depending  on  the  water  level  in  the  filtration  chamber.  In  the  percula 
aquarium, this water level can be adjusted by means of the adjustment plate for the water level in 
the  inflow  compartment  to  the  trickle  filter.  This  adjustment  plate  can  also  be  used  for  the 
regulation  of  the  skimmer.  If  the  water  is  heavily  polluted,  and  the  foam  production  is  huge,  the 
bayonet  socket  (3)  can  be  changed  to  the  elongation  piece  (5).  In  this  case,  the  cover  of  the 
percula  will  not  fit.  After  a  short time,  the  foam production  should  be  self  regulated,  so  the  short 
bayonet socket can be used again and the elongation can be removed. 
 

Air bubbles: 

If the skimmer is added to an existing aquarium there may be a high concentration 

of  organic  substances  already  dissolved  in  the  water.  This  results  in  very  tiny  bubbles  in  the 
skimmer.  These  tiny  bubbles  remove  the  organic  substances  effectively,  however  it  may  be  that 
some  of  these  bubbles  are  drawn  back  into  the  aquarium.  After  a  few  days,  the  concentration  of 
organic  substances  will  have  decreased  to  such  low levels  that  this  effect  will  have  gone  and  the 
water flow is free of air bubbles. 
 
Some types of frozen food may have the same effects. It is best to thaw and wash the food prior to 
feeding it to the fish. The air bubbles will stop after a short period by themselves. 
 

Wet  foam:

  With  freshly  prepared  sea  water,  after  using  water  conditioners  or  at  extremely  high 

loading, excessive wet foam may be produced. This wet foam is forced into the cup, requiring more 
frequent emptying than normal. After approximately one day the aquarium load will be normal, and 
the skimmer will produce the correct foam. 

Summary of Contents for Turboflotor Percula

Page 1: ...schieden Er ist speziell für den aquaristischen Gebrauch entwickelt worden und wurde von Fachleuten erprobt Mit diesem Gerät sind Sie bei richtiger Anwendung in der Lage die organischen Inhaltsstoffe Ihres Aquarienwassers wirksam zu entfernen GmbH Gewerbepark 24 49143 Bissendorf Germany __________________________________________________________________________________________ ...

Page 2: ...es Abschäumers 1 Deckel 2 Schaumtopf 3 Bajonett 4 O Ring 5 Verlängerung für Schaumrohr Option 6 Reaktionsrohr 7 Innenrohr 8 Zulaufrohr 9 Netzkabel 10 unteres Bajonett 11 Halteplatte mit Gummisaugern 12 Dispergatorpumpe 13 Luftansaugstutzen und Luftansaugschlauch 14 Luftregulierhahn 15 Schalldämpfer 16 Halteklammer 17 Halteplatte mit Gummisaugern Abb 1 Turboflotor Percula ...

Page 3: ...an mit Hilfe der Halteplatte am Aquarium oder Filterbecken immer oberhalb des Wasserspiegels Die Luft wird durch die drei rotierenden Nadelscheiben in feinste Luftblasen zerschlagen Darüber hinaus wird durch diese Konstruktion die ansonsten starke Geräuschentwicklung vermieden Die eingezogene Luftmenge sollte so eingestellt sein dass mind 75 des Reaktionsrohres mit Luftblasen gefüllt sind Nach der...

Page 4: ...mpe ausgebaut und das gesamte Kreiselgehäuse und das Nadelrad mit sauberem Wasser ausgespült Auch die Lufteinzugsdüse sollte dann gereinigt und mit frischem Wasser gespült werden 8 Störungen Störungen des Betriebes können auftreten wenn die eingezogene Luftmenge und die Wassermenge nicht mehr im richtigen Verhältnis stehen Dies kann folgende Ursachen haben Die Lufteinzugsdüse ist verstopft oder da...

Page 5: ...t Ihrem Gerät auftreten wenden Sie sich bitte an Ihren Fachhändler Diese Garantie gilt nur für den Erstkäufer Sie deckt nur Material und Verarbeitungsfehler die bei bestimmungsgemäßem Gebrauch auftreten Sie gilt nicht bei Schäden durch Wasser Transporte oder unsachgemäße Behandlung Fahrlässigkeit falschen Einbau sowie Eingriffen und Veränderungen die von nicht authorisierten Stellen vorgenommen wu...

Page 6: ...lected a top quality product It has been specifically designed for aquarium use and has been tested by experts This unit will efficiently remove the dissolved organic substances in your aquarium water GmbH Gewerbepark 24 49143 Bissendorf Germany _________________________________________________________________________________________ ...

Page 7: ...pipe 7 Inner tube 8 Inflow tube 9 Power cable 10 Bottom bayonet 11 Holder with rubber suction cups 12 Venturi pump with needle wheel 13 Air injection nozzle and air hose 14 Air regulation valve 15 Silencer 16 Clip 17 Holder with rubber suction cups The Turboflotor Percula consists of the following parts Foam cup cover and reaction pipe a venturi pump included AB Aqua Medic needle wheel ...

Page 8: ...to small bubbles This method eliminates the greater proportion of the noise The quantity of drawn air should be adjusted so that 75 of the reaction pipe is filled with air bubbles After the initial start some hours may pass before the first foam is pushed into the collection cup This is due to a reaction between the surface of the acrylic glass and the aquarium water Equilibrium of electrical char...

Page 9: ...pair or at our option replace the defective part free of charge always provided the product has been installed correctly is used for the purpose that was intended by us is used in accordance with the operating instructions and is returned to us carriage paid The warranty term is not applicable on the all consumable products Proof of Purchase is required by presentation of an original invoice or re...

Page 10: ...lease ensure you have read and understood the operating instructions If you have any questions your dealer cannot answer please contact us Our policy is one of continual technical improvement and we reserve the right to modify and adjust the specification of our products without prior notification AB Aqua Medic GmbH Gewerbepark 24 49143 Bissendorf Germany Technical changes reserved ...