background image

P L U G - I N   T R A N S F O R M E R   –   I N S T A L L A T I O N   I N S T R U C T I O N S   &   O W N E R S   M A N U A L

INSTALLATION INSTRUCTIONS

1

   Find a suitable location for the mounting of the Transformer. It should be mounted undercover and at 

least 500mm off the ground.

2

   Use the Template provided on this sheet to drill mounting screw holes at 93mm apart. Screws and wall 

plugs are provided. Mount the transformer onto the mounting screws. See 

Diagram D

.

3

   To connect the light cables: first remove 20mm of outer cable sheath and then bare back the two 

sheathed conductors to expose 8mm of tinned copper. See 

Diagram A

.

4

   Locate the Connectors, which are supplied in a plastic bag. Affix each of the cables to the connectors 

and tighten screws, see 

Diagram B

.  

Align and push the connectors into the receptacles on the underside of the transformer, See 

Diagram C

.

5

   Plug transformer into a 240v power point, turn pool lights on to test 

for a maximum of 10 seconds

.  

Then leave pool lights off until fully submerged.

2

Automatic Pool Cleaners (Australia) Pty Ltd

40 Percy Street, Auburn NSW 2144
Ph: 02 9643 8338  Fax: 02 9643 8448
www.aquaquip.com.au

COPYRIGHT AUTOMATIC POOL CLEANERS (AUSTRALIA) PTY LTD    TAPL5142p_1116

93mm

Mounting Holes Template

TRANSFORMER

12 VOLT

120VA

4

 

QUAD  

OUTLET

20mm

93mm

8mm

Diagram A

Cables

Diagram B

Connectors

Diagram D

Mounting

Tighten screws

Diagram C

Underside of transformer