background image

3

C A L L   F O R   S E R V I C E   4 8 0 - 8 9 4 - 0 7 7 0

A q u a S c i e n c e A Z . c o m

3

Solutions For Life

IMPORTANT: Before installing this reverse osmosis system, make 

certain your water supply complies with the following operating speci-

fications. Failure to do so may reduce the effectiveness of the system 

and will void the warranty. 

SPECIFICATIONS

Thin Film Composite Membrane:

Feed Water Pressure:

Temperature Range:

TDS (Total Dissolved Solids):

Maximum Hardness †: 

Sulfide, Iron and Manganese:‡

Chlorine in Water Supply:

pH Limits:

Turbidity: 

TFC

40 to 80 psi

40-100°F 

2000 ppm

10 gpg (171 mg/l)

0 ppm <0.1 ppm

Less than 2 ppm

3-9

11 NTU Average

 If the hardness of your water is above 10 gpg (171mg/l), lime scale 

will build up rapidly on the membrane. Scale buildup will plug the 

membrane and make the system ineffective. We do not recommend 

these reverse osmosis systems to be used with water in excess of 10 

gpg (171mg/l) hardness.

‡A maximum total level of approximately 0.01 ppm sulfide, iron or 

manganese is permissible. Should your water exceed this, see your 

local dealer to reduce these substances in your water.

PARTS INCLUDED:

Pre-assembled and leak tested filter system (mounting bracket, 

membrane housing, membrane, pre-filter housings, pre-filter cartridges 

and post-filter).

* Reverse Osmosis Membrane 

 

*Storage Tank

* Inlet supply adaptor 

 

 

*Drain saddle

* Feed Tubing (1/4-inch)   

 

*Tank Tubing (3/8”)

Tank 

valve 

   *Faucet 

Tubing 

(3/8”)

SYSTEM DIMENSIONS

Overall Dimensions: 

 

14” W x 5 1/2” D x 17” H

Weight: 

   17.3 

lbs. 

(dry)

Tank Dimensions  

 

10” Dia. x 14” H

Tank Capacity Max: 

 

2.8 Gallons

Tank Air Pressure Empty   

7 to 10psi

NOTE:

•Your water must be within required limits for satisfactory operation. If not, 

your membrane life may be shortened and your warranty will be voided.

•This reverse osmosis system will not protect against disease-causing 

bacteria or remove naturally-occurring harmless bacteria.

• Install on cold water line only.

• Do not use wicking or sealer to fitting connections into the cap of the 

filter. Plumber tape is recommended.

• Make certain that installation complies with all state and local laws and 

regulations.

• The replacement cartridges and reverse osmosis membrane 

included with this system have limited service lives. Changes in 

taste, odor, and color of the water being filtered indicate that the 

cartridge should be replaced (see Replacing the Pre- and Post-Filters, 

and Replacing the Membrane).

• After prolonged periods of non-use (such as during a vacation) it is 

recommended that the system be flushed for 5 minutes and the tank 

drained before it is used.

• A drinking water cartridge may contain carbon fines (very fine black 

powder). After installation, flush the system for 5 minutes to remove the 

carbon fines before using the water.

• It is recommended that you run the tap at least 20 seconds prior to using 

water for drinking or cooking purposes.

• The contaminants or other substances removed or reduced by this water 

treatment device are not necessarily present in your water.

Summary of Contents for CLEAR MAX

Page 1: ...Owners Manual A q u a S c i e n c e A Z c o m m o r e s o l u t i o n s b e t t e r p r o d u c t s g r e at s e r v i c e Applicable to CLEAR MAX PURE MAX and ecoRO 4 and 5 Stage Models...

Page 2: ...difference it makes TO KEEP WATER IT S FRESHEST In addition to heavy usage it is a good idea to drain your storage tank once a week Before you go to bed open your faucet and let the water run down th...

Page 3: ...Tank valve Faucet Tubing 3 8 SYSTEM DIMENSIONS Overall Dimensions 14 W x 5 1 2 D x 17 H Weight 17 3 lbs dry Tank Dimensions 10 Dia x 14 H Tank Capacity Max 2 8 Gallons Tank Air Pressure Empty 7 to 10p...

Page 4: ...area is required to allow faucet base to rest securely The faucet fits through a 3 4 inch hole Most sinks have pre drilled 1 1 2 inch or 1 3 8 inch diameter holes designed for spray hoses The drinking...

Page 5: ...h the tubing Do not kink tube Cut the tubing squarely below the nut and remove the internal and external burrs 2 Loosen the compression nut two complete turns Insert the black tubing into the nut unti...

Page 6: ...es are harmless but may make the water appear gray in color The carbon fines are flushed from the system with the first tank full of water Note The reverse osmosis system does not produce a high volum...

Page 7: ...alve on top of storage tank 3 Turn off water supply to RO system at the cold water supply 4 Open drinking water faucet to relieve pressure 5 Locate tubing permeate leading to your drinking water fauce...

Page 8: ...cts to the inlet side of the filter and the elbow attaches to the outlet side NOTE Hand tighten fittings then tighten with a wrench 1 4 turn CAUTION CAUTION The rubber O ring provides the water tight...

Page 9: ...bing Unscrew the tank valve from storage tank Rewrap threads on top of tank with at least 5 8 wraps of plumbers tape Screw tank valve back onto tank Trim 1 2 from end of tubing and reinsert 5 8 back i...

Page 10: ...R V I C E 4 8 0 8 9 4 0 7 7 0 A q u a S c i e n c e A Z c o m 10 Solutions For Life SERVICE LOG Date of Installation ____________________________________ Serial ____________________________________ D...