Contents:
Page
Comments on energy efficient controls
4
Control keys:
ECO, Filter, Heating
5
Menu functions: Menu language; filter pump menu
6
Heating menu
6, 7
Backwash menu
7
Overflow tank menu; ECO menu
8
Configuration menu
9
Important informations
10
Wiring diagram AS Control Plus 11
with Badu Prime, Delta, Profi and Alpha Pump
12
with Pentair IntelliFlow VSD and control IntelliComm II 13
with Pump UWE EO PM
14
with frequency converter AS
15
with frequency converter Invertec 16
Menu diagram 17
The AS Control Plus includes:
1. Comments on energy efficient controls
2. Backwash and rinse controls or control of the compressor
3. Heating controls with frost protection, priority and delay-slop safety
4. Leve1 control of the overflow tank
5. Control of overflow tank (backwas( from the pool or the overflow tank)
6. Energy efficiency control (economy or overflow Operation)
7. Shortcut for starting a backwash and changing the heating setpoint
8. All data for the previous ten-month period are stored. These can
be downloaded onto a PC for analysis.
9. Optional flow control with a paddle switch
Technical data:
Connectors:
78 connectors for inputs and outputs
Relays:
13 relays
Electrical input:
14 VA
Electronic motor protection: for 3-phase, max. 8 amps per phase
Fuse:
4 per 10 amps
Display:
4 layer multilayer
IP Protection:
casing: IP 65
Memory card:
for data storage and evaluation via PC
Temperature probe:
laser-trimmed semiconductor with +/-1 % accuracy
Water and air:
temperature probes are volt-free
Installation
■
The ASCP must be installed in a place free from humidity
■
Wiring of components must be carried out according to the ASCP wiring diagram
■
The regulations of the local electricity authorities must be observed
02-2019 EN AS Control Plus