02-2019 EN AS Control Plus
7
HYSTERIS (factory setting 0.5 °C)
By pressing the OK key the hysteresis can be adjusted between 0.1 °C and 5 °C by means of the
arrow keys. Hysteresis means the number of degrees Celsius, which separate the switching ON and
OFF.
FILTER DELAY STOP (factory setting 3 minutes)
By pressing the OK key the filter run-on time can be adjusted between 1 and 200 minutes by means
of the arrow keys. The run-on time can help to stop a build-up of heat in the system by ensuring that
the filter pump continues to run after the heating has been switched off. If a run-on time has been set
via terminals 24/25 and/or 31-33, this time will be added to the run-on time for the filter.
DELAY STOP TERMINAL 24/25 (factory setting 0 minutes)
By pressing the OK key the filter run-on time can be adjusted between 1 and 200 minutes by means
of the arrow keys.
DELAY STOP TERMINAL 31-33 (factory setting 0 minutes)
By pressing the OK key the filter run-on time can be adjusted between 1 and 200 minutes by means
of the arrow keys.
HEATING PRIORITY (factory setting OFF)
The heating can also be switched on outside the filter operation times. By pressing the OK key the
heating priority can be switched off or set to a temperature difference of between 1 °C and 10 °C for
heating priority.
BACKWASH: (factory setting Friday)
By pressing the OK key the backwash can be completely switched off or the day of the week changed
or an interval of 1 to 30 days between backwash cycles chosen by means of the arrow keys.
BACKWASH VIA: (factory setting overflow tank)
By pressing the OK key you can select, by means of the arrow keys, whether the backwash takes
place via the overflow tank or the main drain.
DELAY STOP VIA OVERFLOW (factory setting 30 minutes)
After every backwash there is a compulsory flow via the overflow channel. The time is adjustable
between
0 and 200 minutes.
START TIME (factory setting 10.00 am)
By pressing the OK key you can select the time at which the backwash starts.
DURATION: (factory setting 4 minutes)
By pressing the OK key you can select, by means of the arrow keys, the duration of the backwash
between 1 and 30 minutes.
PAUSE (factory setting 30 seconds)
By pressing the OK key you can select whether you want to pause between each individual step.
The duration of the pause can be set, by means of the arrow keys, to between 30 and 200 seconds.
RINSE (factory setting OFF)
Press OK. With the arrow buttons you can turn rinsing ON/OFF or select compressor. The duration of
the rinsing can be set between 1 and 200 seconds. If you choose the setpoint „compressor“ you can
connect a compressor instead of a backwash valve. It will turn on before and during the backwash
(Pause = Lead time). The compressor will be activated as well during overflow mode.
BACKWASH MENU
TEST BACKWASH
By pressing the OK key a backwash cycle can be started manually.
The progress of the backwash cycle can be observed on the display.
Shortcut: Press the Filter button for 4 seconds to start a backwash.
➔
➔
➔
➔
➔
➔