02-2019 EN AS Control Plus
9
When choosing „air purge“ you can air purge the filter before backwashing with a solenoid valve.
ADDITIONAL FUNCTIONS:
By pressing the OK key, the additional functions from the settings menu can be hidden. The operator
cannot access them any more. The additional functions remain as set and are active although they are
not visible in the menu.
TIME OF DAY: By pressing the OK key you can select, by means of the arrow keys, the current time.
Even after switching off the AS Control Plus the time is preserved by means of a back-up CR2032
battery.
DATE: By pressing the OK key you can select, by means of the arrow keys, the current date. Even
after switching off the AS Control Plus the date is preserved by means of a back-up CR2032 battery.
PASSWORD: (default: 0.0.0.0)
By setting a password the menu is only accessable after entering the correct password
0.0.0.0 means no protection
START DELAY: (factory setting 10 seconds)
By pressing the OK key you can select a start time delay between 0 and 3600 seconds. The start
delay is always active if: the power supply connected, after a failure of the power supply, when the
filter pump starts. By means of the start delay the outputs for heating, regulation and forced start
are locked.
POOL TEMPERATURE CORRECTION: By pressing the OK key you can adjust by means of the arrow
keys the actual pool water temperature shown in the blue display by up to +10 °C to -10 °C. This fine
adjustment is useful when there is a difference between the measured and actual pool temperature
due to the positioning of the temperature probe.
AIR TEMPERATURE CORRECTION: By pressing the OK key you can adjust by means of the arrow
keys the actual air temperature shown in the blue display by up to +10 °C to -10 °C. This fine
adjustment is useful when there is a difference between the measured and actual pool temperature
due to the positioning of the temperature probe.
TEMPERATURE PROBE AIR: (factory settings: ON). By pressing OK you can enable or disable the
indication of the value.
SERIAL NUMBER: By pressing OK the Serial number will be indicated
CONTROLLER-ID: Press OK to see the Controller ID.
SAVE PARAMETERS: By pressing OK all adjusted parameters will be written to the SD-memory card.
READ PARAMETERS: By pressing OK all saved parameters will be copied to the AS-Control Plus.
FACTORY SETTINGS: By pressing the OK key you can enter the factory settings menu. If you answer
the questions by pressing the OK key, all the values which you have set can be reset to the original
factory settings. All set values are stored electronically and can be recovered even after a power fai-
lure. The date and time are stored by means of a back-up battery which has a life of three to four
years. By removing the four screws on the front panel you can access this battery without any special
tools.
MENU CONFIGURATION:
Time control or air purge Clamp 29/30:
By pressing the OK key you can set up the potential-free contacts on
terminals 29 and 30 according to the wiring diagram with a time interval
of between 1 and 30 days or with a weekly time programme. You can
select up to nine operation times between 00:00 and 23:59. This contact
can be set up in such a way that it is only closed when in addition to the
time programme, the Filter pump, dosing pump or heater is running. The
operating times of the time programme can be erased and
re-programmed.
➔
➔
➔
➔
➔
➔
➔
➔