background image

25/02/15 rev4

 

L0200210 

5/32 

– WHAT IS REVERSE OSMOSIS 

 

Osmosis  is a  natural  phenomenon  for which  poor  in  mineral  salts  solution  passes 
through a semi permeable membrane to dilute a salt mineral richer water.  

Applying  an  opposite  pressure  this  procedure  is  reversed  and  REVERSE  OSMOSIS  is 
achieved:  actually  pushing  a  high  mine

ral  salt’s  concentration  solution  against  a  special 

membrane,  the  result will  be  PURE WATER.  As  a matter  of  fact,  the membrane,  for  it’s 
structure  and  properties,  retains  almost  all  the  solved  salts,  heavy  metals,  polluting 
elements, bacteria and virus, allowing the water to pass by in all its genuine purity. 
REVERSE OSMOSIS is definitely the safer and prevalent water purification system in the 
world; the advantages, with a basic reliability of the process, are represented by an easy 
installation, low exercise costs ant total absence of need for chemical products. 
 

ARO 

systems can remove from the water all the impurities and polluting agents harmful to 

health.  The  resulting  pure  water  represents  the  ideal  solution  for  domestic,  food  & 
beverage  use,  since  it’s  exclusive  filtration  system  forms  a  safety  barrier  against  the 
various polluting agents that could be present in water mains. 

ARO 

systems  reverse  osmosis  depuration  system

 

is  made  with  the  highest  quality  level 

components.  Commonly  manufactured  for  professional  uses,  this  product  has  been 
studied and designed for domestic applications. 

    

 

 

 

 

 

 

 

– TECHNICAL FEATURES 

 

General Description 

Bad  tastes,  smells  and  turbidity  are  often  the  alarm  that  indicates  the  presence  of 
dangerous  polluting  agents  in  the  water  supply  system.  For  example,  insecticides, 
sulphates, cleaning products, substances coming from corroded pipe lines, algae, viruses, 
and bacteria, are all harmful for adult’s and children’s health and consumption.  
Other than that, many polluting agents are not immediately perceptible and visible by man 
without  a  deep  analysis.  To  radically  remove  polluting  agents  from  waters  for  civil  and 
industrial purposes, reverse osmosis system model 

ARO 

offers the most effective method 

to  obtain  good  and  pure  water,  a  possession  becoming  day  by  day  more  precious. 
Reverse osmosis system is made of a pre-treating system composed of a sediment filter 5 
µm,  a  filter  with  activated  carbon  and  a  second  sediment  filter  1  µm;  then  comes  a 
BOOSTER pump activated by a 24VDC motor. The reverse osmosis membrane is held in 
a special vessel fully made in Polypropylene for food & beverage use.  
 
 

Summary of Contents for A9020090N

Page 1: ...25 02 15 rev4 L0200210 1 32 REVERSE OSMOSIS SYSTEM SISTEMA AD OSMOSI INVERSA ARO DUPLEX ARO TRIPLEX ARO TRIPLEX PLUS Use and Maintenance Manual pag 3 Manuale di Uso e Manutenzione pag 13 ...

Page 2: ...25 02 15 rev4 L0200210 2 32 For other languages visit http aqua quickris com l0200210 osmosi aro ...

Page 3: ...TIONS 4 3 WHAT IS REVERSE OSMOSIS 5 4 TECHNICAL FEATURES 5 5 PACKAGE CONTENT AND STOCKING INSTRUCTIONS 7 6 INSTRUCTIONS FOR A REGULAR FUNCTIONING 7 7 INSTALLATION PROCEDURE 8 8 DEVICE STARTING 10 9 MAINTENANCE 10 10 WARRANTY 11 11 SERVICE RECORD TABLE 12 ...

Page 4: ...r bad functioning turn off the osmotic device and do not tamper it For any intervention call an authorized technician in case of substitution of osmotic system s spare parts for maintenance or for breaks by a non authorized technician ensure that the spare parts are in compliance with the law whenever the power supply cable gets damaged it must be substituted by the manufacturer or in any case by ...

Page 5: ...y barrier against the various polluting agents that could be present in water mains ARO systems reverse osmosis depuration system is made with the highest quality level components Commonly manufactured for professional uses this product has been studied and designed for domestic applications 4 TECHNICAL FEATURES General Description Bad tastes smells and turbidity are often the alarm that indicates...

Page 6: ...minal production 190 l day 50 usGPD with 20 C 68 F water temperature and TDS 300 ppm salt level Water Pressure range 0 5 3 bar 7 25 43 5 PSI Max salt level TDS 1000 ppm Treats water with or without chlorine Max permitted chlorine CL2 1 5 ppm Water temperature 5 35 C 41F 95F Materials Pre filter housing and membrane vessels are made of high density polypropylene Pre treatment cartridge contains cer...

Page 7: ...orks with water lower than 5 C 41F or in ice exposed areas Water supply pressure must not exceed 3 bars 43 5PSI or be less than 0 5 bars 7 25 PSI With min flow rate 100 l h 0 44 usGPM for pressures higher than 3 bars 43 5 PSI or in case of water hammer a pressure regulator is necessary Never start the device in absence of water That would irreparably damage the pump and system In case of continuou...

Page 8: ... the installation verify the availability of room enough for a comfortable extraction of the spare parts and for maintenance nonetheless to host the storage tank Verify the presence of a power supply nearby The osmotic device is designed to be installed in an hygienically appropriate and freeze protected area Before proceeding with installation consider the necessary room for hydraulic connections...

Page 9: ...ank to be connected to the storage tank 3 To Faucet to be connected to the treated water supply faucet 4 To Drain to be connected to the waste water drain Water supply pressure has to be lower than 3 bars 43 5PSI and possibly higher than 0 5 bars 7 25PSI Faucet connection Install the faucet by drilling an adequate hole in the kitchen sink and installing it with the supplied accessories ...

Page 10: ...n of filtering elements and the systems sterilization Maintenance frequence Type Use Average life First stage Sediment cartridge 5 μm 3 months Second stage CARBON BLOCK cartridge 3 6 months Third stage Sediment cartridge 1 μm 3 months Fouth stage RO membrane 50GPD 2 3 years Fifth stage CARBON in line cartridge 1 year Membrane substitution procedure Proceed as follows Turn off power supply Unplug h...

Page 11: ... art 13 DL 151 dated 25 07 2005 directives 2002 95 CE 2002 96 CE 2003 108 CE please be aware that Electrical and electronic devices are not to be considered domestic waste It is compulsory by law for the users to return said devices at the end of their life to appropriate disposal gathering centres Barred waste can symbol on the product manual and packing indicates the product as subject to this n...

Page 12: ...25 02 15 rev4 L0200210 12 32 11 SERVICE RECORD TABLE Model Serial Number Installation date DATE 1st STAGE 2nd STAGE 3rd STAGE MEMBRANE POST IN LINE TDS PPM FLOW RATE ...

Page 13: ... COS È L OSMOSI INVERSA 15 4 CARATTERISTICHE TECNICHE 15 5 CONTENUTO DELL IMBALLO E NORME DI STOCCAGGIO 17 6 NORME PER UN REGOLARE FUNZIONAMENTO 17 7 PROCEDURA DI INSTALLAZIONE 18 8 MESSA IN FUNZIONE 20 9 MANUTENZIONE 20 10 GARANZIA 21 11 TABELLA RIEPILOGO MANUTENZIONI PERIODICHE 22 ...

Page 14: ... spina in caso di guasto o di cattivo funzionamento spegnere l osmotizzatore e non manometterlo Per qualsiasi intervento rivolgersi ad un tecnico autorizzato in caso di sostituzione di parti dell osmotizzatore per manutenzione o per guasto da parte di un tecnico non autorizzato assicurarsi che dette parti siano conformi alle normative vigenti qualora il cavo di alimentazione venga danneggiato esso...

Page 15: ...i inquinamenti delle falde acquifere Il sistema di depurazione ad osmosi inversa modello ARO è costruito da componentistica di assoluto livello qualitativo E un prodotto che normalmente viene realizzato per l uso professionale in questo caso è stato studiato e configurato per l uso domestico 4 CARATTERISTICHE TECNICHE Descrizione generale Sapori sgradevoli cattivi odori e torbidità sono spesso il ...

Page 16: ...emperatura acqua 20 C e salinità TDS 300 ppm Pressione acqua 0 5 3 bar Per pressioni maggiori si raccomanda l uso di un riduttore di pressione Max salinità TDS 1000 ppm Acqua da trattare clorata o non clorata Max cloro CL2 ammesso 1 5 ppm Temperatura acqua 5 35 C Materiali impiegati I contenitori dei prefiltri ed i vessel delle membrane sono in polipropilene ad alta densità La cartuccia di pretrat...

Page 17: ... l acqua inferiore ai 5 C o in locali esposti al gelo La pressione dell acqua di alimentazione deve essere compresa tra il massimo di 3 atm ed il minimo di 0 5 atm con portata min di 100 lt h Per pressioni superiori a 3 atm o in caso di colpi d ariete è indispensabile un regolatore di pressione Non fate mai funzionare l apparecchio in mancanza d acqua ciò danneggerebbe irrimediabilmente la pompa P...

Page 18: ... per un agevole estrazione delle parti di ricambio e per la manutenzione nonché per alloggiare il serbatoio di accumulo Verificare che esista una presa di corrente nelle immediate vicinanze dell apparecchio dove poter inserire la spina di alimentazione solo modello PLUS L osmotizzatore è stato progettato per essere installato in un luogo igienicamente idoneo protetto dal gelo Prima di procedere al...

Page 19: ...k da collegare al serbatoio di accumulo 3 To Faucet da collegare al rubinetto di prelievo dell acqua trattata 4 To Drain da collegare allo scarico dell acqua di scarto La pressione dell acqua di alimento non deve essere superiore a 3 Bar e preferibilmente non inferiore a 0 5 Bar Collegamento rubinetto Installare il rubinetto forando il piano del lavello e fissandolo con gli accessori in dotazione ...

Page 20: ...pensabili sono la periodica sostituzione delle cartucce Filtranti e la sanitizzazione dell impianto Frequenza di sostituzione parti Tipologia Utilizzo Vita media Primo stadio Cartuccia a Sedimenti 5 μm 3 mesi Secondo stadio Cartuccia CARBON BLOCK 3 6 mesi Terzo stadio Cartuccia a Sedimenti 1 μm 3 mesi Quarto stadio Membrana Osmosi 50GPD 2 3 anni Quinto stadio Cartuccia in linea al Carbone 1 anno P...

Page 21: ...imettere l alimentazione alla pompa e procedere con la messa in funzione dell osmosi Informazioni per la protezione ambientale Ai sensi dell art 13 del DL n 151 del 25 07 2005 attuazione delle direttive 2002 95 CE 2002 96 CE 2003 108 CE si comunica che I dispositivi elettrici ed elettronici non devono essere considerati rifiuti domestici I consumatori sono obbligati dalla legge a restituire i disp...

Page 22: ...25 02 15 rev4 L0200210 22 32 11 TABELLA RIEPILOGO MANUTENZIONI PERIODICHE Modello Numero Seriale Data Installazione DATA 1 STADIO 2 STADIO 3 STADIO MEMBRANA POST IN LINE TDS PPM PORTATA ...

Page 23: ...25 02 15 rev4 L0200210 23 32 REVERSE OSMOSIS SYSTEM SISTEMA AD OSMOSI INVERSA ESPLOSO EXPLOSE ARO DUPLEX ...

Page 24: ...25 02 15 rev4 L0200210 24 32 ...

Page 25: ...25 02 15 rev4 L0200210 25 32 ...

Page 26: ...25 02 15 rev4 L0200210 26 32 REVERSE OSMOSIS SYSTEM SISTEMA AD OSMOSI INVERSA ESPLOSO EXPLOSE ARO TRIPLEX ...

Page 27: ...25 02 15 rev4 L0200210 27 32 ...

Page 28: ...25 02 15 rev4 L0200210 28 32 ...

Page 29: ...25 02 15 rev4 L0200210 29 32 REVERSE OSMOSIS SYSTEM SISTEMA AD OSMOSI INVERSA ESPLOSO EXPLOSE ARO TRIPLEX PLUS ...

Page 30: ...25 02 15 rev4 L0200210 30 32 ...

Page 31: ...25 02 15 rev4 L0200210 31 32 ...

Page 32: ...25 02 15 rev4 L0200210 32 32 For other languages visit http aqua quickris com l0200210 osmosi aro ...

Reviews: