It allows you to visualize and
change the
percentage
of
chlorine the generator has to
produce, during operation
under normal conditions.
It allows you to view and
change
the
percentage
amount of chlorine that the
generator has to produce,
during operation in Winter
Mode.
Visualize and change the
value set for the chlorine set
point.
Item displayed only if the
type of unit includes the
presence of chlorine Jumo
probe, and the operation is
"proportional".
Visualize and change the
value set for the Redox set
point
choosing
among
0…1000 mV.
Item displayed only if the
type of unit includes the
presence of Redox probe,
and
the
operation
is
"proportional".
Visualize and change the
value set for the pH set point
choosing among
5.0… .9.0
.
Item only appears if the
control unit includes the
presence of the pH probe.
Visualize and change the
value set for the pH work
mode
choosing
between
acid or alkaline
.
Item only appears if the
control unit includes the
presence of the pH probe.
Visualize and change the
value set for the salinity set
point
choosing
between
0.0…5.0 g/l
or
0…5000 ppm
Visualize and change the
value set for the polarisation
period from
1 to 16 hours.
To learn what Polarisation is,
see par. 2.2
4.5.7
Alarms
Menu
The Alarms Menu allows to enable or disable the alarms. Read more about the Alarms menu sections at section
5.
•
Press and hold Enter for 1 second to go back to the "Alarms" section of the
Installer
Menu.
Select how to connect the control box of the device to
the PC. You can choose among:
•
RS232
•
Bluetooth
Select the address within the range 1-99 used in the
Modbus communication protocol. It is recommended
not to change the default value (1)
Ice alarm
Cell Service
Cell Replacement
Cell Service alarm
reset
Cell
replacement
alarm reset
4.5.8
Communication
Menu
The
Communication
Menu modifies some characteristics about the communications between the
device and the user programme installed on the PC.
•
Press and hold Enter for one second to go back to the Communication section of the Installer
Menu.
Modbus
address
Connection
type
Connection
Type
Modbus
Address
Cell replacement
Confirm? Yes/No
Enter
Cell maintenance
Confirm? Yes/No
Enter
Chlorine set
point
Rx set point
pH set point
pH work mode
Salinity set point
Polarisation
Chlorine (base)
Chlorine (WM)