Residential Steambath Generator Systems

3

Before Installing

IMPORTANT:

The following general information should be used in conjunction with consultations with your

architect, designer and contractor in determining all factors necessary in providing a suitable and safe steam
room.

R ead these instructions before installation or service. Although this steambath generator has been qualified for
shipment, the following must be reviewed for proper, safe and enjoyable steam bathing.

Verify that the model and accessories are correct, including incoming line voltage.

Insure steambath generator has been correctly sized for the steambath room. Pay particular attention to room
volume and construction. If any questions, please refer to the sizing guide enclosed. (see page 2).

Marble or glass walls or ceilings, or exterior walls “ E NLAR GE ” the room’s size, requiring a generator larger
than one based only on the room’s cubic foot (L x H x W) volume.

The physical size of the unit, clearance for plumbing servicing, and its distance from the steam room must
all be considered before final installation.

IMPORTANT:

Aquasteam units are intended to be operated with aquasteam controls only, and

are to be installed strictly in accordance with the specific instructions contained in this manual.

ELECTRICAL SHOCK HAZARD.

Aquasteam steam generators are intended for connection to 240V/1ph/60Hz power supply and contain live

electrical components. All lnstallation and service to be performed by qualified and licensed electricians and
plumbers only. Installation or service by unqualified persons may void the warranty.

Steam Room Guidelines

1. S team room must be completely enclosed, with full walls, door, floor and ceiling.

2. It is recommended that a gasketed door is used for heat sealing and steam containment.

3. If tile-type or other smooth surfaced flooring is used provide suitable anti-skid strips or equivalent, to prevent

user slipping and injury.

4. Walls and ceilings must be constructed of water-resistant, non-corrosive surface, such as tile, marble, molded

acrylic, or other non-porous material. The ceiling should be sloped to prevent dripping of condensate. If
acrylic, fiberglass or other non-heat resistant materials are used as part of the steamroom enclosure, see pg.
5, "S teamhead" for additional details.

5. Provide a floor drain.

6. No heating, venting or air conditioning devices should be installed inside the steam room.

7. S team room construction information is available from the Tile Council of America, Inc. by purchasing the

TCA Handbook for Ceramic Tile Installation. Tel: (864) 646-8453 or www.tileusa.com.

8. Windows that are part of the steamroom should be double paned tempered glass.

9. Try to limit steamroom ceiling height to 8 feet. E xceeding 8 feet may require a higher-rated steam generator.

10. It is strongly recommends that a warning

be posted in a conspicuous location near
the steambath. A peel-offwarning has been
provided (on the inside front cover) for
installation. S ee Warning facsimile here.

!

warning

!

warning

REDUCE THE RISK OF OVERHEATING AND SCALDING

1. EXIT IMMEDIATELY IF UNCOMFORTABLE, DIZZY OR SLEEPY.

STAYING TOO LONG IN A HEATED AREA IS CAPABLE OF CAUSING OVERHEATING.

2. CHILDREN UNDER THE AGE OF 16 SHOULD NOT USE THE STEAM BATH.
3. CHECK WITH A DOCTOR BEFORE USE IF PREGNANT, DIABETIC, IN POOR

HEALTH OR UNDER MEDICAL CARE.

4. BREATHING HEATED AIR IN CONJUNCTION WITH CONSUMPTION OF ALCOHOL,

DRUGS, OR MEDICATION IS CAPABLE OF CAUSING UNCONSCIOUSNESS.

5. DO NOT CONTACT STEAM HEAD OR STEAM AT THE STEAM HEAD.

REDUCE THE RISK OF SLIPPING AND FALL INJURY

1. USE CARE WHEN ENTERING OR EXITING THE STEAM ROOM. FLOOR MAY BE SLIPPERY.

NOTE: FOR ADDITIONAL SAFETY CONSIDERATIONS SEE OWNER’S MANUAL

PUR

100378HDCA 6.4/08

WARNING

!

aquabrass.com

  Aquasteam 

steam

generators are for residential use only. Commer-
cial for other non-residential applications void 
the warranty and may adversely affect product 
preformance.

Summary of Contents for Aquasteam ABSC02782

Page 1: ...Installation Operation Maintenance Manual Residential Steambath Generator Systems Leave with Homeowner Leave with Homeowner aquabrass com ...

Page 2: ...rain Safety Valve Generator Dimensions 6 Electrical Specifications 7 Wiring Diagrams 7 Field Power Wiring 8 Start up Maintenance 8 Optional Automatic Drain System 9 _____________________________________________________ Aquasteam In Shower Controls Installing the In Shower Control 12 13 Installing the Remote Temperature Probe 10 11 Operation of In Shower Control 14 Care Tips 14 Replacement Parts Di...

Page 3: ..._________________ MODEL NO ______________________________ SERIAL NO MODELS _____________________________________ _____________________________________ _____________________________________ warning caution M A DE IN U SA LISTED STEAM B ATH GENERATOR 777D REDUCE THE RISK OF OVERHEATING AND SCALDING 1 EXIT IMMEDIATELY IF UNCOMFORTABLE DIZZY OR SLEEPY STAYING TOO LONG IN A HEATED AREA IS CAPABLE OF CA...

Page 4: ...Room Model No KW Vol ft3 cu meters Compare the Total Cubic Feet required h to the Specification Chart below and select the appropriate model Note To convert cubic feet ot cubic meters divide cubic feet by 35 3 Example Total cubic feet required is 155 Divide by 35 3 to obtain 4 39 m3 Select model ABSC02787 IMPORTANT The guideline for selecting the steambath generator is a recommendation only Becaus...

Page 5: ...rovide suitable anti skid strips or equivalent to prevent user slipping and injury 4 Walls and ceilings must be constructed of water resistant non corrosive surface such as tile marble molded acrylic or other non porous material The ceiling should be sloped to prevent dripping of condensate If acrylic fiberglass or other non heat resistant materials are used as part of the steamroom enclosure see ...

Page 6: ...nd top of the steam generator or as required for servicing See page 6 10 Provide unions as required to facilitate installation and disconnection of piping 11 IMPORTANT Steam line safety valve drain valve plumbing and steamheads become hot during operation and remain hot after shutdown for a period of time Provide appropriate protection including insulating plumbing lines Avoid plumbing runs and st...

Page 7: ... steam Steam Head 1 2 NPT INSTALLER Because the steam head and direct steam emissions are very hot locate the steam head where incidental contact by bather with the steam head or direct steam emission cannot occur 1 Locate steam head 6 12 inches 15 30 cm above floor except for Tub shower enclosures install 6 in 15 cm above tub top edge For enclosures with acrylic or other non heat resistant floori...

Page 8: ...8 251 ___________________________________ C 11 7 8 302 12 1 2 310 ___________________________________ D 14 3 4 375 18 3 4 466 ___________________________________ E 1 3 4 45 1 3 4 45 ___________________________________ F 1 7 8 48 2 3 8 60 ___________________________________ G 5 1 8 130 4 102 ________________ __ _________________ H 5 127 6 152 ___________________________________ I 6 3 4 171 7 7 8 20...

Page 9: ...el No Volume ft3 m2 KW phase Amperes AWG mm2 _______________________________________________________________________________________ ABSC02787 225 6 37 7 5 240 1 32 8 10 _______________________________________________________________________ ABSC02789 360 10 19 9 0 240 1 38 8 10 __________________________________________________________________________ _____________________________________________...

Page 10: ...eam will shut offautomatically when control timer reaches zero To shut steam offmanually turn control OFF To clear steam from enclosure area turn shower on before opening door 4 If unit does not start and control does not turn ON control display does not light up then turn breaker off for twenty seconds and try again Maintenance steambath generators require little maintenance Other than periodic d...

Page 11: ...tallation Instructions 1 Disconnect all power supplied to the unit 2 Plumbing to be performed by a qualified licensed plumber and shall be in accordance with applicable National and Local Codes Unit drains by gravity A drain line that is lower than the Automatic Drain assembly must be available The Automatic Drain valve outlet is threaded 1 2 NPT Check plumbing code for receptor trap and vent requ...

Page 12: ...E PROBE DO NOT LOCATE THE PROBE NEAR OR ABOVE THE STEAMHEAD ASTHIS MAY CAUSE DIRECT STEAM EMISSION TO INTERFERE WITH STEAMROOM TEMPERATURE REGULATION 2 Drill a 5 16 inch 8 mm diameter hole in the wall as shown in Diagram 1 Do not oversize or undersize the hole Clean area thoroughly 3 Remove the knock out from the steam generator jacket as shown in Diagram 2 4 Insert the remote temperature probe ca...

Page 13: ...mm of the bulb exposed as shown below Insure a minimum of 1 4 in 6mm of the temperature bulb is exposed to the air Failure to do so may result in an inoperative control and a hazardous condi tion The exposed area of the temperature bulb must be free of silicone or any materials that prevent direct exposure to the steam room air Failure to do so may interfere with the ability to sense temperature a...

Page 14: ...he instructions Proceed with installa tion and verification of proper control function IMPORTANT Turn power to the steam generator OFF before installing the control Failure to turn the power offwill result in an inoperable control Step 4 Remove discard peel offpaper to expose adhesive liner as shown Step 5 Run a bead of silicone provided as shown around the edge of the hole IMPORTANT Do not apply ...

Page 15: ...Connection of Aquasteam Control TemperatureSensor Temp Probe Main Control Note Valve should be closed when automatic drain is not installed aquabrass com Residential Steambath Generator Systems 13 ...

Page 16: ...eys will increase or decrease the current temperature setting The new and desired temperature setting Set Point value will remain for 5 seconds on the LED display as a confirmation of the new value you have selected The Set Point indicator shows the desired temperature NOT the actual temperature Temperature can be adjusted in 1 F 0 5 C increments from 105 120 F 40 0 49 0 C When ambient temperature...

Page 17: ...iquid Level Circuit Board ABSP02796 _____________________________________ Transformer ABSP02779 _____________________________________ Water Feed Solenoid ABSP02778 _____________________________________ Contactor ABSC02787 ABSP02775 ABSC02789 ABSP02775 ABSC02782 ABSP02777 _____________________________________ Automatic Drain ABDR02771 _____________________________________ Acrylic Shield ABSP02776 _...

Page 18: ...ng or arising from modification or repair by any person not authorized by aquasteam abuse misuse neglect accident incorrect power line voltage fire freezing flood or other Acts of God AQUASTEAM PRODUCTS MUST BE INSTALLED OPERATED AND MAINTAINED IN ACCORDANCEWITH aquasteam S INSTRUCTIONS FAILURE TO FOLLOWTHE INSTALLATION OPERATION OR MAINTENANCE PROCEDURES OR USE OF UNAUTHORIZED PARTS AUTOMATICALLY...

Page 19: ......

Page 20: ...residential steambath generators and control by aquabrass aquabrass com ...

Reviews: