14
ELECTRICAL SPECIFICATIONS
Each
Pool Pilot® Professional
model has very specific wiring requirements
based on its line voltage and amperage draw.
• Model CHLOR-25 operates at 208 – 240v requiring advanced wiring,
which should only be done by a qualified electrician. 208 – 240v power
needs to be run from your main breaker panel to a safety switch, then into
the
Pool Pilot® Professional
main power box 1. As above, the cord
labeled ORP must be plugged into a controller, or a 120v outlet.
• Your
Pool Pilot® Professional
system
must
be wired to the main pump
power supply, so that if the pump is shut down, the power to your
Pool
Pilot® Professional
system is lost.
ELECTRICAL SPECIFICATIONS AND FUSE SIZING
MODEL:
MAX PRIMARY AC
AMPS
SYSTEM INPUT
VOLTAGE
BREAKER
REQUIRED
PROB28
20.9
208 – 240v
30amp
Fuse sizing:
Model
Fuse size and type
PROB28
30amp dual element, slow blow, RK5 fuse