SEITE 3, B1TKF.DOC, AUG. 11 

Instruction manual of AquaCare 

Trickling Filter TKF

 

Principle 

Trickling filter are aerated very good and so bio-
logical processes will run faster and gases like 
oxygen and carbon dioxide will be exchanged 
better. The AquaCare Trickling filter TKF can-
not block because the course filter bed  

Mounting the unit 

Place the filter to a practical position. Especially 
the large filter must be protected against falling 
over (brackets are available at your shop).  
If sun will shine at the filter protect it with a 
black foil. Bacteria normally do not like bright 
light.  
You can decide between a rigid PVC tubing or 
connecting with hoses. For hose-mounting un-
screw the upper union nuts of the inlet ball valve 
(1) and the outlet union (2). Take away the in-
serts and replace them with the adapters (3). 
Screw the union nut with the adapters back to 
the union respectively the ball valve.  

Water Inlet

: connect the water inlet (A) of the 

filter with suitable pump or bypass. The needed 
water flow is listed in the chapter “technical 
data”.  

Water outlet

: please connect the outlet (B) back 

to the aquarium system (directly into the aquar-
ium or into the main filter tank). The outlet tub-
ing should not exceed 2 Meter high (pay atten-
tion to the right pump performance). If the outlet 
is higher than 30 cm the “aeration modus” (caps 
E and D are unscrewed) cannot be realized.  
Close the drain (C) if available.  

Filling the system with the filter bed (if not 
delivered with filter material)

: open the filter 

by unscrewing the plastic screws (11). Take off 
the filter cap (10) and the upper filter strainer 
(8). Fill in the delivered special trickling material 
into the filter. Do not fill more than barely under 
the upper end of the central tube (5).  

Attention

! The filter material should not enter 

the central tube (5). Put one of your fingers onto 
the central tube while filling or use a cap.  
After putting back the upper filter strainer (8) 
closed the filter again. Do not forget the o-ring 
and screw all plastic screws (11) tight.   
The filter is now ready to start.   

Putting into operation 

Before putting into operation make sure that all 
connectors are positioned in the right way. The 
drain (C) should be closed.  
Close the inlet ball valve (1) nearly totally and 
start the inlet pump or open the bypass. The wa-
ter should run carefully into the filter.  

Open the ball valve only in small steps. The 
more you open the water inlet valve the higher 
the biological activity.  

“Aeration modus”: 
If you open the screw caps D and E of the aera-
tion and de-aeration connector air will flow up-
wards (chimney effect). This modus should be 
use only if the filter is inside of a filter sump or 
small water leakage does not care. 

Maintenance of the TKF filter 

The filter is nearly maintenance-free. Only if the 
water contains a lot of calcium and hydrogen 
carbonate (alkalinity) lime will fall out on the 
surface of the trickling filter material. After a 
long time of operation it is possibly necessary to 
change the filter material.  

Warranty 

You have 24 months warranty on all AquaCare 
units excepts spare parts like pump bearings and 
rotors. You have no warranty if parts are broken 
by violent.  

Technical data see last page

 