11
UV lamp operational
display panel
To verify that all the UV lamps are operating properly,
your UV treatment unit has been provided with a UV
Lamp Operational Display Panel. The panel consists of as
many LED indicators as there are ultraviolet lamps. Each
LED indicator is electrically connected to the lamp
circuitry of a specific UV lamp. The LED indicators are
intended to operate “on” when the UV lamps are also
turned “on”.
Should any UV lamp fail to operate electrically, the
corresponding LED will automatically turn “off”.
Each UV lamp is numbered at the end of the UV
treatment chamber, and the corresponding LED light
carries the same number on the display panel; thus, if
one or more LED lights fail to operate, you can easily
determine which specific lamp requires attention.
We recommend you monitor the LED Panel daily to
ensure proper performance
.
Running time meter with lamp LED indicator.
prior to turning on the
UV unit, verify the following:
• With water flowing through the system, ensure there
are no system leaks and no piping connection leaks
• All earth ground connections are properly made
• All lamp connections are properly made
1. Verify that all incoming power conductors, including
the ground conductor, are properly terminated.
CAUTION! Rapid succes-
sive cycling of the power to
the ballasts can cause
premature failure of the
system components.
running time meter
Your ultraviolet treatment unit has been furnished with a
Running Time Meter, located on the front instrument
panel. This non-resettable running time meter will log
up to 99,999 hours. It is intended to remind you of the
number of operating hours on the equipment, as certain
maintenance functions need to be performed at certain
time intervals.
A maintenance log is attached to the unit for your use. It
should be kept current. This provides an immediate
maintenance reference: when it was performed and
when the next service is due. Additional service logs are
available from Aquafine, and are intended to be placed
on top of the existing service logs.
2. Turn on the electrical power to the UV unit.
3. Turn the power off until actual operational start up
begins.