CLOCK

The clock, if set, will show the time of the day (24 hour clock).

To set the clock

The machine must be in the “OFF” position.

1. 

Press “CLOCK” once – the first two digits on the LED screen will    

 

flash.  Using the    or    scroll to the required hours.

2. 

Press “CLOCK” again – the second two digits on the LED screen    

 

will flash.  Using the    or    scroll to the required minutes.

3. 

Press “CLOCK” again to set the time.

Note:  It is not necessary to set the time, unless you want the machine to 

show the correct time of day or should you make use of the “TIMER ON” 

and “TIMER OFF” function.

TIMER

You can only switch the machine “ON” and “OFF” once in a 24 hour cycle, 

i.e. the timer has only one setting, therefore the timer is not used to switch 

the heat pump “ON” and “OFF” several times a day, but merely used to 

stop the heat pump from starting up for a set time in a 24 hour cycle, e.g. 

during the night should the heat pump be close to a bedroom window.

How to Set The Timer  “ON” 

(time when machine needs to start up in 

a 24 hour cycle)

Whilst the machine is in the “OFF” position, i.e. showing time, press 

“TIMER ON” twice.  The first two digits on the LED screen will flash.  

Use the    or    to set the required hours.  Press “TIMER ON” again.  

The last two digits on the LED screen will flash.  Use the    or    to set 

the required minutes.  Once the minutes have been set, press “TIMER 

ON” again to save the time setting.

3

 

How to Set The Timer  “OFF”

 (time when machine need to run in 24 

hour cycle)

Whilst the machine is in the “OFF” position, i.e. showing time, press 

“TIMER OFF” twice.  The first two digits on the LED screen will flash.  

Use the     or     to set the required hours.  Press “TIMER OFF” again.  

The last two digits on the LED screen will flash.  Use the    or    to set 

the required minutes.  Once the minutes have been set, press “TIMER 

OFF” again to save the time setting.

Once the “TIMER ON” and “TIMER OFF” is activated, the LED above 

the “TIMER ON” and “TIMER OFF” will light up.

If the “TIMER ON” is activated, but the “TIMER OFF” is not activated 

the heat pump will run continuously, as if the timers are not set.  

However, if the “TIMER ON” is not activated and the “TIMER OFF” 

is activated, the heat pump will run until the “TIMER OFF” time is 

reached and the machine will switch off permanently.

How to deactivate “TIMER ON” and “TIMER OFF”

The heat pump must be in the “ON” or “OFF” position.  Press “TIMER 

ON” twice.  The LED above “TIMER ON” will flash.  Press “CLOCK”.  

The LED above “TIMER ON” will not be illuminated.  “TIMER ON” is 

now deactivated.  

To deactivate “TIMER OFF”, the heat pump must be in the “ON” or 

“OFF” position.  Press “TIMER ON” twice.  The LED above “TIMER 

ON” will flash.  Press “CLOCK”.  The LED above “TIMER ON” will not 

be illuminated.  “TIMER OFF” is now deactivated.  

4

Summary of Contents for Keypad

Page 1: ...ature you can only view the settings In order to change the settings the machine must be in the OFF position i e showing time The rate of heating the water will be the same it does not matter what the required set temperature is i e by setting the temperature very high this won t increase the rate of heating By setting the required temperature too high this will only cause a higher electricity con...

Page 2: ... will flash Use the or to set the required minutes Once the minutes have been set press TIMER ON again to save the time setting 3 How to Set The Timer OFF time when machine need to run in 24 hour cycle Whilst the machine is in the OFF position i e showing time press TIMER OFF twice The first two digits on the LED screen will flash Use the or to set the required hours Press TIMER OFF again The last...

Page 3: ...To set the inlet water temperature when in cooling mode 8 28 C Default setting 27 C Parameter 3 Defrost starting temperature Defrosting function 30 0 C Default setting 6 C 5 Parameter 9 Pump 0 always open 1 10 sec start before compressor starts 30 sec stop after compressor stops Inlet water temperature HOW TO SET THE PARAMETERS The machine must be in the OFF position Press or to scroll until you r...

Page 4: ... Coil 2 sensor failure D The sensor is open or short circuit Check or change the sensor PP5 Ambient temperature sensor failure E The sensor is open or short circuit Check or change the sensor PP6 Temp differential between water in and water out is too high Water flow volume too low water pressure difference is too low Check the water flow volume pressure PP7 Machine in defrost mode Ambient or inle...

Page 5: ... blanket you will not be able to maintain a constant temperature in your swimming pool A good example to think of is driving your car with the air conditioning on and all the windows down WHY IS THERE WATER DRIPPING FROM UNDER THE HEAT PUMP When the heat pump is running in the heating mode condensation build up on the evaporating coils will cause water dripping under the heat pump This is a normal...