PARAMETERS

There are 10 variable parameters (0 – 9) which can be set.  There are 5 

fixed parameters (A – E) which are for information only.

Parameter 4

Defrost exit temperature.  

Defrosting function (0 –

 

30˚C).  Default setting:  

13˚C.

Parameter 5

Maximum time of 

defrosting (0 –

15min).  Default 

setting:  8 min.

Parameter 2

Heating time when 

in defrost mode

Parameter 1

To set the inlet water 

temperature when in

 

heating mode (15 – 40˚C).  

Default setting:  27˚C

Parameter 6

System Quantity 

(don’t set).

Parameter 7

Automatic restarting

0 – No

1 – Yes

Parameter 8

Mode:

0 (cooling only)

1 (cooling & heating)

2 (auxiliary elec. heating)

3 (heating only)

Parameter 0

To set the inlet water 

temperature when in

 

cooling mode (8 – 28˚C).  

Default setting:  27˚C.

Parameter 3

Defrost starting 

temperature.  Defrosting 

function (-30 – 0˚C).  

Default setting:  -6˚C.

5

Parameter 9

Pump:

0 (always open)

1 (10 sec. start before compressor 

starts. 30 sec. stop after 

compressor stops)

Inlet water 

temperature

HOW TO SET THE PARAMETERS

The machine must be in the “OFF” position.
Press    or    to scroll until you reach the required parameter.
Press “MODE” and “ON/OFF” switch simultaneously and release.  (NB 

quick press and release!).

The parameter value will start flashing.  Use the     or    to change the 

value to the required setting.  Wait until the LED has reverted back to time.  

A new parameter setting is programmed.  
Press      to restart the machine.

Outlet water

 

temperature

Condenser 1

 

temperature

Condenser 2

 

temperature

Ambient 

temperature

6

Summary of Contents for Keypad

Page 1: ...ature you can only view the settings In order to change the settings the machine must be in the OFF position i e showing time The rate of heating the water will be the same it does not matter what the required set temperature is i e by setting the temperature very high this won t increase the rate of heating By setting the required temperature too high this will only cause a higher electricity con...

Page 2: ... will flash Use the or to set the required minutes Once the minutes have been set press TIMER ON again to save the time setting 3 How to Set The Timer OFF time when machine need to run in 24 hour cycle Whilst the machine is in the OFF position i e showing time press TIMER OFF twice The first two digits on the LED screen will flash Use the or to set the required hours Press TIMER OFF again The last...

Page 3: ...To set the inlet water temperature when in cooling mode 8 28 C Default setting 27 C Parameter 3 Defrost starting temperature Defrosting function 30 0 C Default setting 6 C 5 Parameter 9 Pump 0 always open 1 10 sec start before compressor starts 30 sec stop after compressor stops Inlet water temperature HOW TO SET THE PARAMETERS The machine must be in the OFF position Press or to scroll until you r...

Page 4: ... Coil 2 sensor failure D The sensor is open or short circuit Check or change the sensor PP5 Ambient temperature sensor failure E The sensor is open or short circuit Check or change the sensor PP6 Temp differential between water in and water out is too high Water flow volume too low water pressure difference is too low Check the water flow volume pressure PP7 Machine in defrost mode Ambient or inle...

Page 5: ... blanket you will not be able to maintain a constant temperature in your swimming pool A good example to think of is driving your car with the air conditioning on and all the windows down WHY IS THERE WATER DRIPPING FROM UNDER THE HEAT PUMP When the heat pump is running in the heating mode condensation build up on the evaporating coils will cause water dripping under the heat pump This is a normal...