21
Commissioning – Colt exposed continued
6. Relocate the cam into the cam locking ring and turn the shaft sleeve through 180º (one half turn) to lock the
cam down.
7. Depress the red stop button and replace the temperature control knob in the full cold position and secure
using the fixing screw.
8. Test the shower by turning it on and slowly increasing the temperature. At the selected point, the button
should pop up and prevent further movement. Repeat the above process if the maximum temperature stop
button needs further adjustment.
9. When the stop button is at the desired limit, refit the screw cover in the control knob.
Should the shrouds need to be removed at any time, turn the knob fully clockwise to the off position.
Carefully depress the left hand side of the badge in the middle of the front shroud fascia using a suitable
tool taking care not to damage the badge or the surrounding plated surfaces. The right hand side of the
badge will lift clear of the recess enabling you to remove the badge, giving you access to the small screw
fixing the shroud in place. Remove the screw and lift the top shroud assembly clear. Remove the two fixing
screws from the valve assembly and pull the bottom shroud clear.
Should the knobs need to be removed at any time, turn the knob fully downwards to the off position.
Remove the screw covers from the middle of the control knobs with a suitable tool taking care not to
damage the surrounding plated areas. Remove the fixing screws and pull the knob clear.
Should unacceptable damage to the badge occur when removing it from the recess, please contact Aqualisa
customer services who will send a free of charge replacement.