3. Cable sizes detailed are the minimum acceptable sizes. Sizes
greater than these shown above may be used and should be
used if cable runs are greater than indicated (above cable runs
are based on a maximum 9.6V drop).
4. Rewirable fuses are not recommended and not covered by
this table.
5. Installation should be carried out by a qualified person.
Please refer to BS7671 (Wiring Regulations) if in doubt.
6. A 16mm² cable may be required for longer cable runs.
Cables which are chased into the wall must be protected by
the use of conduit or sheathing. Surface mounted cables must
also be protected by a suitable approved conduit.
Before removing the shower heater cover, ensure the heater is
isolated from the electric mains.
Quartz™ Electric is suitable for household use only.
Flushing
Some modern fluxes can be extremely corrosive and, if left in
contact, will attack the working parts of this unit. All soldering
must be completed and the pipework thoroughly flushed out
in accordance with current Water Supply Regulations prior to
connection of the product.
Connections
Quartz™ Electric is suitable for use with 15mm British Standard
pipe and should be connected using a 15mm compression
fitting (not supplied). Quartz™ Electric is suitable for bottom,
top or rear entry pipework and cable. Supply lines should be
flushed clear of any debris prior to installation of the unit.