9
Fig. 2: Venturi pump DC Runner 3.0
1. 4 Rubber feet
9. Hose connection pressure side
2. Retaining plate
10. Union nut pressure side
3. Pump motor
11. Connection for air hose
4. Rear ceramic bearing
12. O-ring suction side
5. Rotor incl. 3D needle wheel
13. Reduction for air intake nozzle
6. Housing’s sealing
14. Union nut suction side
7. Pump head
15. Pump basket
8. Seals for pressure connection 16. Sealing plug
The pump DC Runner 3.0 is operated by an electronic safety transformer at AC 100 – 240 V / 50 –
60 Hz and 24 V DC output. Power consumption of the pump is 21 watts, protection rating is IP X8.
To open the pump, remove retaining plate and release the housing’s sealing (6) by turning it.
DC Runner Control
The included
DC Runner
Control is switched between power supply and pump to adjust the output.
The power can be adjusted by pressing the +/- buttons, the level is displayed by LED. If you press
the button „FEED“, the output will stop for 10 minutes. Controller, transformer, plugs and sockets
have to be kept dry.
Fig. 3: DC Runner Control