13
6.3
General overview of Menu structure
Menu level 1
Menu level 2
Menu level 3
description
el
CountEr
Counter values (totalizers)
trIP-Cnt
Trip counter (subtotals)
InStAnt
Instant values
InFo
only visible if an alarm or error is active
OP_hourS
Operating hour information
bILLInG
option -xx-xC
only visible with option MID005
LoGGEr
Log values
unLoc
enter code to unlock and edit values
LoG
only visible with user code
OutPutS
Digital outputs
Int-BUS
Internal bus communication in single mode
UnItS
Units
ConFIG
System configuration
SYS-SEt
System settings
SYSINFO
System Information
DisplayTest
displays all characters on the display
Some menu items only visible based on preset conditions (e.g. compensation of/off)
Only visible if option MID005 is set / ordered
Access / edit level
el
none
0
user
1
user (
without option “C” MID)
2
Supervisor / manager
3
Service technician
4
production
5
no edit, read only
Compensation to Norm-Volume and Mass flow calculation: (Config/CM)
Compensation to norm-volume and Mass flow can be turned on, this means that the volumetric
expansion of the medium is calculated using actual temperature and normalized to the actual vol-
ume at 15°C. this value is also used to calculate mass / mass flow.
The display and outputs parameters are added accordingly
NOTE
Visability of counters and modification of settings
•
Counters and settings related to compensation and mass calculation, are only
visible or functional if compensation under menu “ConFIG/CM”
is turned on to
either “SGL OIL” or “dbL OIL” compensation