background image

 

 

 

 

 

 

  

 

 

 
 
 
 
 
 

 
 
 

 Connect the insulated black high temperature steam pipe, which is on the steam outlet, to the steam 

jet’s connector on the spa’s back panel

. (Figure 10)   

 
 
 
 
 
 

 

 
 
 
 
 
 
 

The water hose for the rainfall shower goes 

through the hole in the shower roof /ceiling and then connect 

it 

to the elbow fixture of the shower head with a clamp as is shown in the below figures.

 (Figure 11)

 

 
 
 
 
 
 
 
 
 

Black  insulated  high  temperature 

steam pipe 

Front and side view of Steam outlet

 

 

Figure 10 

Figure 11 

Rainfall shower hose 

When bending the insulated 

steam  hose

, please Use Extreme Care not to crimp the hose as 

you feed it through the appropriate hole in the tub section.     

 

The rubber washer (gasket) that is secured by a wire tie is inserted into the end of Steam hose 

 

The all silver hose is the water supply feed hose to the Steam generator. It is attached here   

 

Photo  is  not  of  Caribbean.  But  connections  are  the  same.  The  placement  of 
components may be different

.   

Summary of Contents for Caribbean

Page 1: ...0 CARIBBEAN INSTALLATION MANUAL ...

Page 2: ...se keep in mind that like most shiny bathroom surfaces when they get wet they may become slippery Take care not to slip or fall 2 Children should only use this product under adult supervision 3 Users who suffer from heart disease or have high blood presser should exercise greater care when using this product 4 Senior citizens pregnant women and those who are of ill health are advised to get a doct...

Page 3: ...o position during installation 4 Tools Wooden mallet open end wrench level Tape measure Screwdriver Pencil 4mm Hex wrench Electrical data Dimensions inches N W capacity Circuits Power frequency Length Width Height 1 110V 11 8 amps 1 220V 13 6 amps 1300W and 3000W 50 60Hz 63 8 63 8 87 390 lbs 40 Gal Please note If you have purchased a Tub with the additional heater option it is very important to un...

Page 4: ...3 Drain pipe can be offset as much as 6 inches from tub drain 2 2 Installation drawing for waste plug Installation instructions Rough Plumbing Electrical ...

Page 5: ... from the side walls if maintenance is ever needed C Drainage The diameter of the drain pipe needs to be at least 2 inches The position of the drain hole can be within 6 inches from the hole shown in the drawing on the previous page It is also very important that the drain line not have a trap It must be a straight drain line as the shower spa has its own built in trap for your convenience Notes 1...

Page 6: ...gram Figure 2 is below Please insert the rubber gaskets between the glass and aluminum channels where indicated The glass walls are framed by the curved rails on the top and bottom and with the aluminum extrusions to the left and right Connect the left and right fixed glass walls 2c to the upper and lower aluminum curved rails 2d by using 8 pieces 3 16 x 1 inch 2a screws with the plastic chrome sp...

Page 7: ...tion diagram as follows Figure 4 Using x 1 inch bolts 3a connect the left and right small panels 3b 3c to the middle panel 3d respectively to complete the whole back panel of your steam shower 3e Figure 4 1 Figure 4 1 Figure 4 ...

Page 8: ...d the Glass wall and door assembly 3g onto the bathtub attach the glass door to the back board by using3 16x 3 4 inch bolts Figure 4 3 4 Final installation steps Figure4 2 Figure 4 3 Figure 5 Place the ceiling roof of the spa 3i onto the unit then using 1 4x 1 inch bolts bolt it to the back panel and use 3 16x 3 4 inch screws to fasten the roof to the glass wall door Figure 5 ...

Page 9: ...ass door You want the door to be as plumb as possible After the correct positions for the top eccentrics have been determined then you can tighten them as needed Now the bottom eccentrics may be installed using a similar method only no fine tuning is necessary The bottom ones are simply inserted first their lowest position and then twisted 180 degrees to their highest position to lock them into th...

Page 10: ...te outlets inlets are labeled in the above diagram and are visible in the photo below The Steam generator drain hose is pushed onto the fitting straight or elbow connected to the Steam Generator It is secured to this fitting by a clamp and a 3 16 X 5 8 inch round head fastener as is shown in the above figure It is also shown assembled in the photo below Outside of spa Figure 7 4c Figure 8 Steam ou...

Page 11: ...Black insulated high temperature steam pipe Front and side view of Steam outlet Figure 10 Figure 11 Rainfall shower hose When bending the insulated steam hose please Use Extreme Care not to crimp the hose as you feed it through the appropriate hole in the tub section The rubber washer gasket that is secured by a wire tie is inserted into the end of Steam hose The all silver hose is the water suppl...

Page 12: ...e ozonizer O3 shower self cleaner Connect the wires sharing the same labels and or properly mated connector pairs The radio antenna will need to be unrolled and placed for best reception See figure 12 16 Connect the hot and cold water hoses the red one is for hot water while the blue one is for cold Both the hot and cold water supply lines are half inch NPT pipe thread Figure 12 ...

Page 13: ...on the next page Pick a side wall water jet pipe that is convenient to work on Measure the distance taken up by the water heater Approximately 7 and 5 8 inches Cut this part out Glue the ends of the water heater and wait until the glue sets as per the manufactures instructions Plug the heater in It has its own thermostatically controlled on off and temperature controls It will turn on when there i...

Page 14: ... with a high grade silicone sealant Then fully test the unit Then slide it into its final installed position 4 Spray and foot massage installation 4 1 Connect the hose of the hand held shower head B by screwing it into nozzle A as depicted below and then put the hand held shower head into its cradle C Figure 14 Figure13 Figure 14 ...

Page 15: ... massage position water comes out of the left body massage jets When control knob 5c is opened then both sets of body massage jets will work Knob 5a3 adjusts the temperature of the water and knob 5a2 is used to adjust the amount or rate of the water entering the spa The five way selector 5a1 may be set to and from any position even with the water running 4 2 Use the same technique to install the f...

Page 16: ...6 Water route connecting diagram Body ...

Page 17: ...l box or the steam generator Doing so will void your warrantee There are no user serviceable parts inside DO NOT repair or replace these units on your own If you do experience any problems please contact Aquapeutics Toll Free Customer Service line 1 800 290 6812 for after sale service ...

Reviews: