background image

Operation instruction of S198E system

then momently press  once again to enter duration setting mode. As the icon         

 flashes, rotate  the shuttle switch to adjust the time or press         on the  remote 

control to increase the time or           to decrease the time. Timing range: 5 ~ 50min.

. Settings of temperature and time would automatically take effect in 3 seconds,

 the system would exit the temperature and time setting mode.

 Drainage: 5 minutes after the shutdown of system, the steam tank would drain

 water for 3 minutes.

2. Spray(

Optional 

)

      Move the cursor to                  and press the shuttle switch. The first press would

 turn on upper spray; the second press--switch to middle spray; the third press–

switch

 

to lower spray; the fourth press would start the automatic cycle of upper,

 middle and lower spray; the fifth press--switch to overhead spray. There is a

 1-second delay before the overhead

 

spray starts; the sixth press would turn off the

 spray. The spray type would change every

 

5 seconds in the cyclical mode.

      In the case that the remote control is used to control the spray, momently 

press

         

on the remote control. The first press would turn on upper spray; the

 second press--switch

 

 to middle spray; the third press--switch to lower spray; the 

fourth press would start the automatic cycle of upper, middle and lower spray; the

 fifth press would turn off the spray. When the overhead spray is off, press             on

 the remote control to open overhead spray (other sprays are off). Then press the

 button again to turn off overhead spray

.

3 Exhaust fan function

    Move the cursor to                   and press the shuttle switch or momently press            

16

Summary of Contents for WG-U6811

Page 1: ...Installation Manual STEAM ROOM Make the most of your shower make the best for your home WG U6811 Aquapeutics Aquapeutics ...

Page 2: ...ted parts Safety notice Advice 1 Pay attention to high temperatures to prevent burns when using the steam shower 2 Persons that are intoxicated hypertensive asthmatic or have heart disease should avoid prolonged use of the steam shower 3 Children should be accompanied with adult when using the steam shower 4 close the door and do not enter the steam shower when the sterilization is on 5 The massag...

Page 3: ...on Exhaust Fans Control Panel MODEL WG U6811 Product Features Standard Configuration Function and device The information of this table are only reference the company have right to amend the technique parameter specification model collocate before any advance inform the detail please inquire about dealer Water Parameter Work hydraulic pressure Current capacity Diameter of drainer Mpa L min Cold hot...

Page 4: ...he wall which should be 1000mm above from the ground 0 15mPa Pressure 0 4mPa 2 The steamer power 4500W Power supply voltage AC220V 10 Frequency 50Hz Single Phase and Three Wire System with 3X4mm2 rubber insulated copper wire which is independent loop The steamer is mounted with the Creepage Overload Protection device and must have the reliable ground wire Bathtub body 7500W AC220V 50Hz Single Phas...

Page 5: ...SWITCH SMALL WATER MASSAGE JETS 10 UNDER WATER LIGHT AIR JETS 10 VIEWING WINDOW AIR CONDITIONING SWITCH HANDRAILS FOR 4 STORAGE RACK ACUPUNCTURE MASSAGE JETS 12 MEDICINE BOX MIDDLE BACKBOARD LEFT BACKBOARD BATHTUB ALUMINUM FRAME A1 A2 B 2 C 2 D 2 GLASS 2 GLASS DOOR 2 HANDLE 2 WHEEL 4 F SPARE 2 RIGHT BACKBOARD FAN FOOT MASSAGE WATER NOZZLE CUSHIONS 2 MANUAL DRAINER SUCTION ADJUSTABLE BIG WATER MASS...

Page 6: ...stall bathtub Open the packing put the tray to the appropriate place Use the level ruler test all direction is balance Adjust the screw which in foot to the tub until level and then screw down the nut The feet must adhere to the ground 5 ...

Page 7: ...Installation Steps M4 16 4 M4 25 8 A1 A1 A1 A2 B B B C C C D D The big single side seal The small single side seal 6 ...

Page 8: ...Installation Steps M6 25Screw 4 M6 25Screw 4 7 ...

Page 9: ...Installation Steps M4 16 5 M6 25Screw 11 F Spare install the wheels install the wheels foot massage shower fitting steam box 8 ...

Page 10: ...ter Connect handheld shower Connect top shower Connect waterfall Connect back jets Connect foot massage Hose diagram Steam Generator Water out Steam box Steam generator Drainer Steam generator water in Note all pipe there must be gasket 9 ...

Page 11: ...n Instruction Of Steam Room Handheld shower Top shower Waterfall Handheld shower Left ON OFF Handheld shower Right ON OFF Foot massage Back jets POWER ON OFF POWER ON OFF AIR PUMP SWITCH WATER PUMP SWITCH AIR CONDITIONING SWITCH 10 ...

Page 12: ... LCD screen Power switch Last song Volume control Next song Shuttle switch 3 3 4 4 1 1 2 2 14 14 8 5 5 6 6 3 3 4 4 6 5 1 1 2 2 1 2 Operation instruction of S198E system 11 ...

Page 13: ... indication Fahrenheit indication none Turning Channel search Bluetooth Keyboard lock Steam temperature setting Telephone answer Sterilization Cursor Optional 2 modes of shortcut key Fan 14 14 14 14 14 14 14 14 14 14 14 14 14 14 Lighting 12 3 3 15 16 12 23 23 20 8 8 27 27 24 27 4 4 13 14 18 9 20 15 7 13 22 19 5 9 26 26 23 26 3 5 5 10 1 1 1 A 17 14 18 10 25 25 22 6 6 11 2 A A A A A 2 2 16 19 8 21 1...

Page 14: ...y Bluetooth function key Turning song switch function key Tune rising function key Steam function key Channel storage function key Setting function key Tune falling function key Radion function key 14 14 14 14 Overhead spray function key 3 3 12 8 4 4 13 9 5 5 1 1 14 10 6 6 2 2 11 7 7 14 14 3 3 8 8 4 4 9 5 5 1 1 6 6 2 2 7 7 11 12 10 14 13 14 14 13 ...

Page 15: ...up Touch on the panelor press on the remote control to turn on the system The back light of shuttle switch and LCD screen would light up the screen would show currenct temperature The system would automatically set a countdown of one hour and turn on the overhead light shutdown When the system is operational and unlocked touch on the panelor on the remote control to turn off the system It would al...

Page 16: ...to turn off the steam function After the steam function is turned on the steam machine would shut down automatically as the steam temperature reaches the set value and reopens as the steam temperature falls below the set value The default steam temperature is 45 and the default duration is 45min Setting of steam bath temperature After turning on the steam machine move the cursor to press the shutt...

Page 17: ... the fourth press would start the automatic cycle of upper middle and lower spray the fifth press switch to overhead spray There is a 1 second delay before the overhead spray starts the sixth press would turn off the spray The spray type would change every 5 seconds in the cyclical mode In the case that the remote control is used to control the spray momently press on the remote control The first ...

Page 18: ...mission of ozone would last 10minutes then the exhaust fan would automatically start and operate for 15 minutes 6 Radio Function Move the cursor and press the shuttle switch or momently press on the remote control to turn on or turn off the radio function Icon would light up after startup Channel search After turning on the radio function move the cursor to and press the shuttle switch or press on...

Page 19: ...rent channels Frequency range 87 5 108 0MHz Switch of channels When the radio is turned on and the panel is unlocked move the cursor to press the shuttle switch rotate the shuttle switch or momently press on the remote control to switch channels and play programs on the stored radio channel 7 Bluetooth Turn on the system and the power supply of Bluetooth module Bluetooth module would connect to ce...

Page 20: ...o or reception of phone calls the cursor can only move between non multimedia functions and phone After the cursor moves to a non telephone icon it would automatically return to the phone icon for no operation in five seconds Multimedia control keys on the remote control will be disabled during ringing and reception of calls When a phone call comes in touch to reject the call 9 Volume control In t...

Page 21: ...again to enter the mode of steaming duration setting then press again to enter volume adjustment mode The fourth press would return to the steam temperature setting As the system enters the volume adjustment mode would begin to flash on the LCD screen Operation instruction of S198E system 20 ...

Page 22: ...fter 1 minute the system would report E10 fault as well as turn off steam function and inlet valve When the system is turned on it shows E16 fault and turn off the steam function Cut off the power and check the temperature probe as well as related lines E18 Communication Fault A Short circuit or open circuit in communication line B Fault of communication driver circuit C Damage of CPU I O port Dur...

Page 23: ...Aquapeutics Aquapeutics ...

Reviews: