ULTRAVIOLET MODULE
CLEANING, SANITIZING, AND CARTRIDGE REPLACEMENT PROCEDURE
14
RECOMMENDATIONS
HAVE ALL COMPONENTS ON HAND AND READY BEFORE BEGINNING PROCEDURE
A CLEAN WORK AREA AND EQUIPMENT ARE ESSENTIAL TO PROPERLY CLEAN AND/OR DISINFECT THE SYSTEM
(i.e., CLEAN HANDS, TOOLS, WORK SURFACE, AND CONTAINERS)
EQUIPMENT NEEDED
Safety Glasses
Rubber Gloves, Sanitary
Wash Cloth, Clean and Lint-Free
Liquid Dish Soap
Household Bleach – Unscented Only
(5 ¼% Sodium Hypochlorite)
Plastic Bucket
“O” Ring Lubricant, Silicone Based
(P/N 30300026)
REPLACEMENT FILTERS
REPLACEMENT UV COMPONENTS
Refer to system Parts List for specific component part numbers
Refer to system Parts List for specific component part numbers
CLEANING PROCEDURE
CAUTION:
Clean all parts (except filters and electronic
parts) with the specified cleaning solution and rinse them
with RO product, distilled, or de-ionized water.
NOTE:
Refer to individual System Assembly and
Activation Procedures to identify specific components
matching the descriptions shown in this procedure.
1. Disconnect system from electrical outlet.
2. Mix a mild cleaning solution of dish soap and clean
potable water in the plastic bucket.
3. Close feed water supply valve and open outlet valve
to relieve system pressure.
4.
CAUTION:
Do not attempt to remove sumps until
water
flow stops. This reduces pressure inside the
system so sumps may be safely removed.
Remove each sump. Use sump wrench to remove
stubborn sumps. Remove each filter as its sump is
removed. Discard the filters.
5.
CAUTION:
Use sanitary rubber gloves for this
procedure to avoid contaminating cleaning solution
or filters. Wear gloves whenever cleaning
components or handling new filters.
CAUTION:
If quartz sleeve is removed or twisted,
replace “O” rings.
Clean quartz sleeve carefully using vinegar to
remove calcium carbonate deposits. Do not use
abrasive materials. Rinse sleeve thoroughly.
Replace any sleeve that is damaged or will not come
completely
clean.
6. Remove sump “O” rings and wash them with
cleaning solution. Rinse “O” rings thoroughly.
Inspect “O” rings for damage (i.e., nicks or
scratches). Replace damaged “O” rings.
7. Clean sumps and heads, inside and outside with
washcloth and cleaning solution. Do not use
abrasive materials.
8. Rinse sumps and heads thoroughly.
9.
For 4.5 and 8.5 GPM Models only:
Clean and
rinse the Stainless Steel Channeling Sleeve (Item 3)
and
Sleeve
Gasket.
10. Inspect head and sump “O” ring groove area for
damage (i.e., nicks or scratches). Replace damaged
components.
WARNING: USE FDA APPROVED SILICONE
LUBRICANT ON “O” RINGS. DO NOT USE
PETROLEUM-BASED LUBRICANTS.
11. Lubricate the sump “O” ring. Install the “O” ring into
the filter sump groove.
DISINFECTION PROCEDURE
WARNING: NEVER LOOK DIRECTLY AT A LIGHTED
UV LAMP.
WARNING: WEAR SAFETY GLASSES AND
SANITARY RUBBER GLOVES WHILE PERFORMING
THIS PROCEDURE.
WARNING: READ THE "WARNINGS" ON THE
BLEACH CONTAINER BEFORE USING.
WARNING: HANDLE SANITIZING SOLUTION
CAREFULLY. AVOID CONTACT WITH
UNPROTECTED AREAS.
1. Disconnect system from electrical outlet.
2.
CAUTION:
Excessive concentrations of
bleach will
damage plastic and rubber components. Rinse all
parts that contact bleach thoroughly with clean
potable
water.
Mix a sanitizing solution of 59 ml (1/4 cup) of
household bleach and 177 ml (3/4 cup) of clean,
potable water in the bucket. Mix the solution well.