background image

4

 

US (866) 877-6637 | 

 

CAN (866) 766-3426 | aquascapeinc.com

•  Always operate the pump fully submerged. Failure to do 

so will overheat the pump and cause it to fail, thus voiding 
the warranty. DO NOT OPERATE DRY.

•  Use only in fully assembled state, and be sure that both 

the upper and lower cage screens are snapped together.  
Failure to operate the pump without the filter cage closed 
will allow large debris to enter the pump, causing the 
pump to fail and voiding the warranty.

•  DO NOT wear loose clothing that may become entangled 

in the impeller or other moving parts.

•  Keep clear of suction and discharge openings. DO NOT 

insert fingers in pump with power connected.

•  DO NOT pump hazardous materials or liquids, such as oil, 

saltwater or organic solvents.

•  DO NOT block or restrict discharge.
•  Products returned must be cleaned, sanitized, or 

decontaminated, as necessary prior to shipment so as 
to ensure that employees will not be exposed to health 

hazards in handling said material. All applicable laws and 
regulations shall apply.

IMPORTANT:

 Aquascape, Inc. is not responsible 

for losses, injury, or death resulting from a failure 
to observe these safety precautions, misuse or 
abuse of pumps or equipment.

AquaForce

®

 Solids-Handling Pond Pump 

Specifications

•  Input Voltage: 120V AC
•  Input Frequency: 60 Hz
•  Submersible pump
•  For outdoor or indoor use
•  Thermally protected
•  This pump has been evaluated for use with water only
•  Input amps & wattage: see chart below

Model Number

1000

1800

2700

3600

5200

Maximum Flow Rate (GPH)

1,070

2,149

2,695

3,868

5,284

Maximum Head Height

10'

16.5'

14'

18'

24'

Motor Type

Asynchronous

Asynchronous

Asynchronous

Asynchronous

Asynchronous

Wattage

55

160

147

215

360

Amperage

.51

1.33

1.25

1.8

3

Power Cord Length

25'

25'

25'

25'

25'

Pump Discharge Diameter

1.5" MPT

 

1.5" MPT

 

1.5" MPT

 

1.5" MPT

 

1.5" MPT

 

Multi-Hose Fitting Diameters

1", 1.25", 1.5", 2"

1", 1.25", 1.5", 2"

1", 1.25", 1.5", 2"

1", 1.25", 1.5", 2"

1", 1.25", 1.5", 2"

AquaForce Solids-Handling Pond Pump Specs

Installation

•  The AquaForce Solids-Handling Pond Pump is designed 

to be submerged directly into the pond. To maximize pond 
circulation, locate the AquaForce pump as far away as 
possible from the location of the water entering back into 
the water feature (Ex. 1).

•  It is recommended that the pump NOT be positioned in 

the deepest area of the pond (Ex. 1). This will protect the 
fish by preventing the pond from completely draining in the 
case of leak in the plumbing or filter. Bricks or stones can 
be used, if needed, to raise the pump up off the bottom of 
the pond.

•  The AquaForce includes a wide assortment of fittings to 

choose from. Select the appropriate fitting(s) needed for 
your application.

•  The threaded collar, on all of the fittings, enables the 

AquaForce pump to be installed and removed without the 
need for any tools (Ex. 2). Do not use tools to attach the 
fittings onto the pump discharge (Ex. 3). Fittings need to 
be hand-tightened only.

Ex. 1

Ex.2

Ex. 3

Summary of Contents for 91011

Page 1: ...HANDLING POND PUMP AquaForce 1000 Solids Handling Pond Pump Item 91011 AquaForce 1800 Solids Handling Pond Pump Item 91112 AquaForce 2700 Solids Handling Pond Pump Item 91012 AquaForce 3600 Solids Ha...

Page 2: ...ase of maintenance makes this pump the ideal choice for discriminating pond owners The AquaForce protective pre filter cage allows the pump to be placed directly into the pond AquaForce pumps are able...

Page 3: ...all a properly grounded receptacle outlet acceptable for outdoor use and protected from snow and rain B Inspect cord before using C Do not use extension cords D Any wiring of pumps should be performed...

Page 4: ...ected This pump has been evaluated for use with water only Input amps wattage see chart below Model Number 1000 1800 2700 3600 5200 Maximum Flow Rate GPH 1 070 2 149 2 695 3 868 5 284 Maximum Head Hei...

Page 5: ...by a ground fault interrupter Ex 10 Once the pump is running and water is circulating check for any leaks where the external connections are made Using the AquaForce as a Winter Bubbler The AquaForce...

Page 6: ...s stuck to the filter cage Ex 14 Internal Pump Cleaning If you have thoroughly cleaned the filter cage screens and still have diminished flow rates then you will need to remove the pump from the lower...

Page 7: ...receiving the correct voltage Pump not working The ground fault circuit interrupter GFCI may have tripped The pump is not receiving the correct voltage Troubleshooting Ex 20 Removing scale build up wi...

Page 8: ...and winterized otherwise warranty is null and void No liability for loss or damage of any nature or kind whether arising out of or from the use of the product whether defective or not defective is ass...

Page 9: ...N AquaForceMD 1000 Solids Handling Pond Pump R f rence 91011 AquaForceMD 1800 Solids Handling Pond Pump R f rence 91112 AquaForceMD 2700 Solids Handling Pond Pump R f rence 91012 AquaForceMD 3600 Sol...

Page 10: ...aquascape4 pinterest com aquascapeinc instagram com aquascape_inc Rejoignez nous sur Les pompes pour filtration et cascades AquaForce asynchrones et r sistantes au colmatage effectuent ce que la plupa...

Page 11: ...de la s curit de l utilisateur E D branchez la pompe de la prise de courant lorsque vous ne vous en servez pas ou avant de la sortir du plan d eau F Pour r duire le risque de d charge lectrique tout...

Page 12: ...la pompe de bassin de traitement des solides AquaForceMD Tension d entr e 120 V c a Fr quence d entr e 60 Hz Pompe submersible Pour utilisation ext rieure ou int rieure Protection thermique Pompe valu...

Page 13: ...ascades ou un filtre pressuris Ex 9 Branchez la pompe un disjoncteur de fuite la terre Ex 10 Lorsque la pompe fonctionne et que l eau circule par le s filtre s ou les cascades v rifiez toute possibili...

Page 14: ...ant les d bris de la cage de filtration Retirez les d bris log s dans la cage de filtration de la pompe et ou utilisez un tuyau d arrosage pour nettoyer les d bris coll s sur la cage de filtration Ex...

Page 15: ...ension D pannage Si l assemblage de la turbine du rotor et la partie interne de la pompe contiennent des d p ts calcaires excessifs nettoyez avec un acide doux comme du vinaigre blanc ou du CLR et une...

Page 16: ...a garantie exclut les co ts de main d uvre de retrait du produit d exp dition et les d penses li es l installation et la r installation du produit Tous les produits qui incluent la plomberie tubes pom...

Reviews: