background image

8

 

US (866) 877-6637 | 

 

CAN (866) 766-3426 | aquascapeinc.com

Warranty Information

3 YEAR WARRANTY

Aquascape warrants that the AquaForce

®

 Solids-Handling Pond Pump will be free of manufacturing defects for three 

years from date of purchase. Proof of purchase required. Warranty does not cover damage resulting from electrical 

supply problems, improper wiring, lightning, negligent handling, misapplication, misuse, or lack of reasonable 

maintenance or care. Warranty does not cover parts subject to normal wear, such as impellers.  This product should 

only be operated in fresh water, completely submerged, without corrosive chemicals like chlorine or bromine. If 

upon Aquascape’s inspection, the pump shows evidence of a manufacturing defect, Aquascape’s liability is limited, 

at Aquascape’s option, to the repair of the defect, replacement of the defective product, or refund of the original 

purchase price. The warranty excludes costs of labor, removal of product, shipping and expenses related to the 

installation and re-installation of the product. All products that include plumbing (tubing, pumps, check valves) need 

to be properly drained and winterized otherwise warranty is null and void. No liability for loss or damage of any nature 

or kind, whether arising out of or from the use of the product, whether defective or not defective, is assumed by 

Aquascape, Inc. or its affiliates. Aquascape shall not be liable for any incidental, consequential or other damages 

arising under any theory of law whatsoever.

No. Item number/description

1. 

91075 

 AquaForce (G2) Replacement Cage Discharge Fitting Kit

2.

91076 

 AquaForce 1000/2700 (G2) Replacement Water Chamber Cover

2.

91077 

 AquaForce 5200 (G2) Replacement Water Chamber Cover

3.

91078 

 AquaForce 1000/1800/2700 (G2) Replacement Pump Cage Kit

3. 

91096 

 AquaForce 3600/5200 (G2) / Adjustable Flow 4000-8000 

Replacement Pump Cage Kit

4.

91079 

 AquaForce (G2) Replacement Cage Clip Kit

5.

91080 

 AquaForce 1000 (G2) Replacement Impeller Kit

5.

91115 

 AquaForce 1800 (G2) Replacement Impeller Kit

5. 

91081 

 AquaForce 2700 (G2) Replacement Impeller Kit

5.

91116 

 AquaForce 3600 (G2) Replacement Impeller Kit

5.

91082 

 AquaForce 5200 (G2) Replacement Impeller Kit

AquaForce

®

 Solids-Handling Pond Pump Replacement Parts

Replacement Parts

x 5

5

2

4

1

3

For more information about our company or products, please visit our website at aquascapeinc.com  

or call us at US (866) 877-6637 CAN (866) 766-3426

©2022 Aquascape, Inc. • All Worldwide Rights Reserved

91074 • 01/22

Summary of Contents for 91011

Page 1: ...HANDLING POND PUMP AquaForce 1000 Solids Handling Pond Pump Item 91011 AquaForce 1800 Solids Handling Pond Pump Item 91112 AquaForce 2700 Solids Handling Pond Pump Item 91012 AquaForce 3600 Solids Ha...

Page 2: ...ase of maintenance makes this pump the ideal choice for discriminating pond owners The AquaForce protective pre filter cage allows the pump to be placed directly into the pond AquaForce pumps are able...

Page 3: ...all a properly grounded receptacle outlet acceptable for outdoor use and protected from snow and rain B Inspect cord before using C Do not use extension cords D Any wiring of pumps should be performed...

Page 4: ...ected This pump has been evaluated for use with water only Input amps wattage see chart below Model Number 1000 1800 2700 3600 5200 Maximum Flow Rate GPH 1 070 2 149 2 695 3 868 5 284 Maximum Head Hei...

Page 5: ...by a ground fault interrupter Ex 10 Once the pump is running and water is circulating check for any leaks where the external connections are made Using the AquaForce as a Winter Bubbler The AquaForce...

Page 6: ...s stuck to the filter cage Ex 14 Internal Pump Cleaning If you have thoroughly cleaned the filter cage screens and still have diminished flow rates then you will need to remove the pump from the lower...

Page 7: ...receiving the correct voltage Pump not working The ground fault circuit interrupter GFCI may have tripped The pump is not receiving the correct voltage Troubleshooting Ex 20 Removing scale build up wi...

Page 8: ...and winterized otherwise warranty is null and void No liability for loss or damage of any nature or kind whether arising out of or from the use of the product whether defective or not defective is ass...

Page 9: ...N AquaForceMD 1000 Solids Handling Pond Pump R f rence 91011 AquaForceMD 1800 Solids Handling Pond Pump R f rence 91112 AquaForceMD 2700 Solids Handling Pond Pump R f rence 91012 AquaForceMD 3600 Sol...

Page 10: ...aquascape4 pinterest com aquascapeinc instagram com aquascape_inc Rejoignez nous sur Les pompes pour filtration et cascades AquaForce asynchrones et r sistantes au colmatage effectuent ce que la plupa...

Page 11: ...de la s curit de l utilisateur E D branchez la pompe de la prise de courant lorsque vous ne vous en servez pas ou avant de la sortir du plan d eau F Pour r duire le risque de d charge lectrique tout...

Page 12: ...la pompe de bassin de traitement des solides AquaForceMD Tension d entr e 120 V c a Fr quence d entr e 60 Hz Pompe submersible Pour utilisation ext rieure ou int rieure Protection thermique Pompe valu...

Page 13: ...ascades ou un filtre pressuris Ex 9 Branchez la pompe un disjoncteur de fuite la terre Ex 10 Lorsque la pompe fonctionne et que l eau circule par le s filtre s ou les cascades v rifiez toute possibili...

Page 14: ...ant les d bris de la cage de filtration Retirez les d bris log s dans la cage de filtration de la pompe et ou utilisez un tuyau d arrosage pour nettoyer les d bris coll s sur la cage de filtration Ex...

Page 15: ...ension D pannage Si l assemblage de la turbine du rotor et la partie interne de la pompe contiennent des d p ts calcaires excessifs nettoyez avec un acide doux comme du vinaigre blanc ou du CLR et une...

Page 16: ...a garantie exclut les co ts de main d uvre de retrait du produit d exp dition et les d penses li es l installation et la r installation du produit Tous les produits qui incluent la plomberie tubes pom...